Installing The Perimeter Wire - Stihl RMI 422 P Manual De Instrucciones

Ocultar thumbs Ver también para RMI 422 P:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

10 Installing the Robotic Mower
► Re-attach the cover (5), taking care not to pinch the power
supply cord or the perimeter wire.
► Connect the docking station only to a covered Class A
GFCI receptacle that has an enclosure that is
weatherproof with the attachment plug cap inserted or
removed and that matches the voltage and electrical
frequency stated on the power supply.
The LED on the docking station will flash red rapidly when
the perimeter wire is installed and properly connected to
the docking station.
► Press the OK button on the control panel / manual
controller.
If an external docking station has been installed, STIHL
recommends defining at least one starting point outside the
corridor to the docking station after initial installation is
complete, @ 15.6.
NOTICE
A canopy top is available to protect the docking station from
the elements. Exposure to direct sunlight can lead to
increased temperatures inside the machine and battery
compartment, which can increase battery charging times
and reduce battery life.
0478-131-3045-A
To charge the robotic mower:
11
► Lift the robotic mower slightly by the rear carrying
handle (11) to relieve the weight on the drive wheels.
► Push the robotic mower, resting on its front wheels, into
the docking station.
The LED on the docking station flashes slowly after
docking.
► Press the OK button on the robotic mower's control panel.
If the battery is discharged, a plug symbol will appear at
the top right corner of the display after docking and the
battery will charge while the perimeter wire is being
installed.

10.4 Installing the Perimeter Wire

WARNING
To reduce the risk of injury to bystanders and unauthorized
users, secure the perimeter wire in the ground with the wire
stakes. Ensure that the perimeter wire and stakes are buried
or properly secured low enough to the ground that they will
not get caught in the robotic mower's mowing blade and will
not present a tripping hazard. To reduce the risk of eye
injury, always wear close-fitting protective eyewear when
installing the docking station and perimeter wire, @ 5.3.
► Before installing the perimeter wire, read the entire
chapter on routing the perimeter wire. Plan the wire
routing in detail, @ 11. In particular, observe the wire
English
23

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido