CLEANING CYCLE

Note: The frequency of cleaning will be determined by the hardness of your water and the amount of use.
1. Before starting, turn the unit off and turn off the water supply to unit.
2. When all ice has melted from the evaporator and fallen into the ice bucket, remove the bucket (being careful not to
spill any water) and discard or store ice in a separate freezer.
Note: If you are using the continuous drain option, the unit must be turned off during the next step. If you are using
the drain pump option (see separate installation instructions), please keep the unit turned on (this allows pump to
operate.)
3. Remove the rubber drain hose from the left front (Fig. H, item 4) of the ice maker cavity. Slowly tilt the drain hose
down towards the drain port at the back right – lower corner of the ice maker cavity. The water will drain into the
drain port. Tilt the drain hose slowly to ensure that the water is not able to overfl ow the ice bucket area. (See
Fig.H)
4. When the water stops coming out of the drain hose, ensure that all water has been drained from water tank area.
(Look inside to check that all water has been drained from water container area.) Check the water tank for any ex-
cess sediment and remove any if present. Flush out tank before reinstalling drain hose in clips. Reinstall the drain
hose by pushing it back into the clips.
5. Fill the water tank with a cleaning solution comprised of equal parts water and vinegar. Next, turn the water sup-
ply on.
6. If the bucket has been removed, reinstall the ice bucket after the water tank stops refi lling, and the unit begins to
run again.
7. Allow the unit to produce 4 - 6 batches of ice, then turn the unit off and allow any remaining ice to fall into the ice
bucket.
8. Remove the ice bucket and discard all (6) batches of ice.
9. If the drain pump mode is being used (see separate installation instructions), turn the unit on at this point. Unit
has to be in the process (operating mode) in order for the pump to work. If unit is in standby mode pump will not
operate. Once again, remove the rubber drain hose from left side clips and slowly drain the cleaning solution into
the drain port in bottom right side of cabinet area.
10. When all of the solution has drained, reinstall the drain hose into the clips, turn water on and allow tank to fi ll. Re-
install the ice bucket. Make sure the reservoir is full before unit is turned back on.
11. Discard the fi rst 2 batches of ice that fall into the ice bucket.
12. Normal ice production can continue when there is no evidence of the cleaning solution remaining in the
unit.
1. Evaporator cover board
2. Direction plate
3. Water container
4. Drain hose
5. Clips
Fig.H