Operating Guidelines

Introduction:
This product is grounded. In the event of an electrical
short circuit, grounding reduces the risk of electrical
shock by providing an escape wire for the electrical
current. This product is equipped with a cord having
a grounding wire with an appropriate grounding plug.
The plug must be plugged into an outlet that is properly
installed and grounded.
Ampere
Rating
Range
(120
25 ft.
Volts)
0-2
18
2-3
18
3-4
18
4-5
18
5-6
18
6-8
18
8-10
18
10-12
16
12-14
16
14-16
16
16-18
14
18-20
14
Fig. B
Minimum Gauge for Extension Cords
50 ft.
100 ft.
150 ft.
18
18
16
16
18
16
18
14
16
14
18
14
14
12
14
10
12
10
12
10
12
8
12
8
This product is for use with a nominal 120 volt or 240
volt (for high voltage applications).
Improper installation of the grounding
plug can result in a risk of electrical shock. If repair
or replacement of the plug or cord is necessary, do
not connect the grounding wire to either flat blade
terminal.
Check with a qualified electrician or serviceman if the
grounding instructions are not completely understood, or
in doubt as to whether the product is properly grounded.
Do not modify the plug provided; if it will not fit the outlet,
have the proper outlet installed by a qualified electrician.
Length of Cord in Feet
200 ft.
250 ft.
16
16
14
14
14
12
12
12
12
10
12
10
10
8
8
8
8
6
8
6
6
6
6
6
10
WARNING
300 ft.
400 ft.
14
14
12
12
12
10
10
10
10
8
10
8
6
6
6
6
6
6
6
4
4
4
4
4
500 ft.
12
12
10
10
10
10
8
8
8
6
8
6
6
4
4
4
4
2
4
2
2
2
2
2
3