Repair
Fluid Inlet Fitting Replacement
PRESSURIZED EQUIPMENT HAZARD
•
Fluid inlet gasket (3) must be replaced if
fluid inlet fitting (4) is removed from spray
gun.
•
Failure to replace gasket (3) may result in
air leakage into the fluid section causing a
non-vented gravity cup to become
pressurized.
1. Remove fluid inlet fitting (4).
2. Remove fluid inlet gasket (3) from gun body
and discard.
3. Apply thread sealant to replacement fluid
inlet fitting (4) threads.
4. Snap the fluid inlet gasket (3) securely onto
the fluid inlet fitting (4).
5. Screw in fluid inlet fitting (4) and torque to
155-165 in.-lb (17.5-18.6 N•m).
6. Replace washer (28) as required.
8