Close-up view showing alignment of fluid tip (item 5 above)
Fig. 10
Fig.28a
1
2
TURBINE UNIT
• Check that the Filter (14) is not clogged
>>up. The filter can be removed for cleaning
>>and washed in hot soapy water. Please
>>dry throughly before reassembly.
• To access the filter, remove the Hose
>>Clip (15) by releasing the two clips at the
>>bottom (Fig.11a). Reassemble in reverse
>>order noting sequence of anchors I and II
>>(Fig.11 b).
• Wipe down external surfaces of the
>>turbine unit until clean. Do not submerge.
• NEVER operate your SprayStation without
>>the Filter (14) fitted.
NEEDLE AND TIP STORAGE
• The Needle and Fluid Tip Tool (1) can be stored in the back of the turbine unit, behind the fitted
>>Hose Clip (15) (Fig.2).
• Any spare needles and tips can be stored on the underside of the Hose Clip (15) (Fig.2a).
• To store the Air Hose (13), wrap around the turbine unit, clipping it into the Hose Clip (15). The end
>>of the air hose can be retained using the Retainer Clip (16).
• The Spray Gun can be stored in the Spray Gun Docking Bay (18) on the rear of the turbine unit by
>>securing the handle of the Spray Gun into the recess.
3
4
5
Fig.11a
Fig.11b
Removing hose
Fitting hose clip
clip
9