10. SPECIFICATIONS
Maximum Continuous Power ....................................................................410 Watts
Surge Capability (Peak Power) .................................................................820 Watts
No Load Current Draw .....................................................................................<0.4A
Wave Form ................................................................................ Modified Sine Wave
Input Voltage Range.....................................................................10.5V – 15.5V DC
Output Voltage Range ....................................................................... 120V ± 5% AC
Low Battery Alarm ............................................................... Audible, 11V ± 0.3V DC
Low Battery Shutdown ...................................................................10.5V ± 0.3V DC
High Battery Shutdown ..................................................................15.0V ± 0.5V DC
Optimum Efficiency ............................................................................................85%
AC Outlet..............................................................................Two, NEMA 5 - 15 USA
USB Port .......................................................................................... One, 5V 2 Amp
Dimensions ................................................................................5" L x 4" W x 2.2" H
Weight .......................................................................................approximately 2 lbs.

11. REPLACEMENT PARTS

12V Accessory Plug with Cables........................................................... 3899001511
Battery Cable with Clamps ....................................................................3899001512

12. BEFORE RETURNING FOR REPAIRS

When an UNKNOWN OPERATING PROBLEM arises, please read the complete
manual and call the customer service number for information. This will usually
eliminate the need for return.
If this does not eliminate the problem, or for information
about troubleshooting, call toll-free from anywhere in the U.S.A.
7:00 am to 5:00 pm Central Time, Monday through Friday
For REPAIR OR RETURN, contact Customer Service at 1-800-621-5485. DO NOT
SHIP UNIT until you receive a RETURN MERCHANDISE AUTHORIZATION (RMA)
number from Customer Service at Schumacher Electric Corporation.