en - Operating instructions
Switch the oven on or the oven
function of your steam combination
oven on and select: Fan plus
200 °C.
During the reactivation process
odours may be given off.
During the reactivation process make
sure that the room is well ventilated.
Open a window if necessary.
Reactivation duration: 60 minutes.
Switch the oven or the oven function
on your steam combination oven off
once this process has finished.
Do not take the charcoal filter out of
the oven whilst still hot and do not
place it on a heat-sensitive surface
whilst hot.
Do not refit it in your cooker hood
whilst still hot!
Leave it in the oven compartment
until it has cooled down.
Place the charcoal filter back in the
recirculation box and refit the
ventilation grille.
If your cooker hood has a charcoal
filter operating hours counter , it
must be reset after reactivating the
filter. Please observe the operating
instruction manual for your cooker
hood for instructions on how to do
this.
Replacing charcoal filters
The charcoal filter should be replaced
every 3 years.
Type: Miele DKF 1000 R.
10
Disposing of charcoal filters
Used charcoal filters can be disposed
of with the normal household waste.
Cleaning the casing
Clean the ventilation grille and the
internal areas of the casing when the
filter has been removed. Use warm
water with a little washing-up liquid
applied with a sponge.