Battery Compartment - LD Systems FX 300 Manual De Usuario

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 23
MIC CH
9
Operating and display elements for the microphone channel.
GAIN – Controls amplification of the microphone signal. The corresponding SIG LED indicator lights up white when a signal is present. If the signal is 1
dB below the distortion threshold, the LED lights up violet. If the instrument input is driven beyond the distortion threshold, the SIG LED lights up red
and signal distortion may occur. Set the Gain control so that the SIG LED does not light up red when there are volume peaks.
TONE – 8 kHz high-shelf equalizer. In the centre position the signal is unaffected. Turn to the left to reduce highs by up to 8 dB. Turn to the right to
increase highs by up to 5 dB.
FX SEND – Level control for mixing the microphone signal with the internal digital effects processor. Ensure that the red FX CLIP LED does not light
up.
10
DIGITAL EFFECTS PROCESSOR
Rotate the encoder to select one of the 16 effects presets. A list of available effects is printed above the preset encoder. The red FX CLIP LED lights up
if the signal reaches the distortion threshold of the internal effects processor. To avoid signal distortion, ensure that the FX CLIP LED does not light
up if there are volume peaks. Reduce the effects send level control FX SEND on the affected channel.
MIX OUT
11
Level control for the combined MIX OUT line out signal. Rotate to the left to decrease and to the right to increase the volume.
FX MUTE
12
Button for muting the effects signal. Push the button to mute the effects signal and once again to unmute it. When muted, the corresponding red
indicator LED lights up.
MUTE ALL
13
Button for muting the combined signal. Push the button to mute the combined signal and once again to unmute it. When muted, the corresponding
red indicator LED lights up.

BATTERY COMPARTMENT

14
Battery compartment for the 9 V block battery. To replace the battery, open the battery compartment by pushing the compartment lid lever in the
direction marked "OPEN" and flip the lid upwards. Remove the used battery, attach the clip to the new battery (1 x 9 V block, alkaline) and insert it
in the battery compartment. Replace the battery compartment cover on the housing and click it into place. If you do not use the device for a long
period, remove the battery to prevent damage to the device from a leaking battery.
PLEASE NOTE: If the 9 V block battery's voltage falls to below 6 V, the SIG indicator LEDs on both channels will light up white simultaneously. Insert a
fresh battery or use a suitable mains adapter.
6
OPEN
14
9V BATTERY
15
15