2.2 Wiring overview
Index
Description
1
Power Supply plug
2
Backup Battery Switch
3
SIM card socket
4
EOLR Hardwired Zones Connections, refer to section 2.3 and the
Hardwired Zones Connections diagram
5
Tamper switch
2.3 Hardwired Zone Connections
Zone 1, Zone 2 and Zone 3 are the EOLR supervised zones that supports both open
circuit and closed circuit devices and has a response time of 300msec. Maximum zone
resistance: 11000 ohms, plus EOLR
Connect closed circuit devices in series in the high (+) side of the loop. The EOL
resistor must be connected in series with the devices, following the last device.
Connect open circuit devices in parallel across the loop. The 10000-ohm EOLR must be
connected across the loop at the last device.
Refer to the Hardwired Zones Connections diagram.
What it it means
System is in Alarm
System is Armed
System is Disarmed
4