6.1.1. Reference standards
Safety:
EMC:
Insulation:
Pollution level:
Measurement category:
Max operating altitude:
Drop test:
6.1.2. General characteristics
Mechanical characteristics
Size (L x W x H):
Weight (batteries included):
Power supply
Battery type:
Low battery indication:
Auto Power OFF:
Fuses:
Display
Conversion:
Characteristics:
Sampling frequency:
6.2.
ENVIRONMENT
6.2.1. Environmental conditions for use
Reference temperature:
Operating temperature:
Allowable relative humidity:
Storage temperature:
Storage humidity:
This instrument satisfies the requirements of Low Voltage Directive 2014/35/EC
This instrument satisfies the requirements of European Directive 2011/65/EU (RoHS)
6.3.
ACCESSORIES
6.3.1. Accessories provided
Pair of test leads
Batteries
Carrying case
User manual
IEC/EN61010-1
IEC/EN61326-1
double insulation
2
CAT III 600V
2000m (6562ft)
3m
120 x 65 x 45mm (5 x 3 x 2in)
200g (7ounces)
2x1.5V batteries type AAA IEC LR03
the symbol
after 15 minutes
F10A/600V, 5 x 20mm (input 10A)
F500mA/600V, 5 x 20mm (input mAA)
TRMS
4 LCD, 4000 dots plus decimal sign, point and
backlight
3times/s
18°C 28°C (64°F 82°F)
5°C ÷ 40°C (41°F 104°F)
<80%HR
-20°C ÷ 60°C (-4°F 140°F)
<80%HR
(LVD) and of EMC Directive 2014/30/EC
and 2012/19/EU (WEEE).
EN - 17
appears on the display
"
"
idling (may be disabled)
'
IRONMETER