StoP
Foyer cleaning.
FirE
− Equipment
Off
09:32
Stop.
− Equipment
Rest.
ST
1
IGNITION OR IGNITION AFTER PELLET TANK EMPTYING
•
Verify that the pellet tank is full, the equipment is connected to the socket and the back
switch is on position 1 ( display control panel is lighted ). During the 1
ignition, the loading member ( screw feeder ) is not load so it's possible that the
equipment will not complete all ignition phases and it raise the alarm ( alar – no Acc ) :
it's necessary to repeat one or more time the following:
1
Push for several seconds the button nr. 4 of control panel – If the initials "alar – No
acc " will appear, carry on as point 2 or wait the initials "On" or "Eco" on display,
to indicate the function power phase;
2
Turn off the equipment, pushing button 4 for several seconds, on panel control;
3
Remove the current through the back button 0 – 1;
4
Remove pellets from burner tank;
5
Recover the current through the back button;
6
Repeat from point 1.
IGNITION – NORMAL CYCLE
•
To check the pellets quantity inside tank than check that the combustion room and the
basket ( with all its holes ) are clean form impurity. After basket cleaning, to insert it
again checking that the big hole correspond to the screw feeder tube placed on right of
combustion room that push for several minutes the button nr. 4 of panel control.
POWER REGULATION
•
It's possible to select the calorific power between the button 5-6 ( on 1.......on 5 ) from
3.0 to 8.0 kW. The optimal regulation of singular function is automatic inside equipment.
It's not possible to modify the calorific power when the stove is in "Eco" modality
( it's go pass the selected temperature environment).
TO BLOCK/UNBLOCK THE PANEL
•
It's possible to block the panel equipment to avoid the use from no technical people. To
activate or deactivate the panel block, keep pressed the button 2 at least 10 sec. the
display signal "bloc" if the panel is blocked, "norm" if the panel is unblocked.
The equipment is executing the foyer cleaning, the pellets
feed is on min. and motor for exhaust fumes is on max.
− The Stop button has been pushed and the equipment start
the turning off cycle.
− The equipment is turn off
45/112
IT-GB-FR-ES mod. 515S-515N
st