Instructions for use and safety
1
General view:
2
Regulation: -Meets UNE EN 60730-2-7 regulations- Follow instructions to compliance with the R.D. 842/2002. - Installation, service and maintenance of the
electrical equipment may be carried out by anauthorized person only.-It complies with the WEEE directive.
3
*Characteristics:-DIN RAIL Installation. -Advanced pre-setting one week before -Digital electronics general purpose time switch with daily and weekly programs -Repeat programs
with 16ON/OFF settings, 18 times pulse programs, and setting on/off manually. -Lithium battery power reserve when electric supply cut
time error correction ±30 sec, weekly.
4
Connection & technical data: LOAD
●Voltage rating: AC220V 50/60HZ
●Hysteresis: ≤2 sec/day(25ºC)
●ON/OFF operation: 16 ON & OFF, 18 times pulse
●Power consumption: 7.5VA( max)
●Minimum interval: 1 minute
5
Instructions:
1.First time use this timer switch, please input power and let battery charge. After then press reset Key. 2.At first time, the timer switch is in 24h mode.If you want
change to 12h mode please press on""Key 5 sec, and LCD will display AM If you want recharge to 24h mode ,and press on""key 5 sec to return.
3.Programming: set on&off same time, have 30 seconds to control bell.
Step Key
Programming
1
Setting 1 ON time(display 1 on)
Press
2
Press H+/M+
Set hours and minutes
3
Press D+
Select days of week. Same everyday, MO - FR,MO-SA,SA-SU,MO-WE,TH-
SA,MO WE FR, TU TH SA, different everyday.(If same everyday, not press
this key)
4
Setting 1 off time ,display 1 off
Press
5
Press H+/M+
Set hours and minutes
6
Press D+
If you want same set in every day,you need not press this key
7
Rep eat step 2 -6
Set 2-16 on/off time
8
End
Press
*If need not 16 pulse press""key to the end.
5. Count down:("d" displays at bottom-left corner of LCD)
Step
Key
Programming
1
Press
&
Into count down
2
Press &H+/M+
Setting min/sec
3
Press MANUAL
Start count down
4
Press
Return to start count down
5
Press P&
Exit
7. Auto time error correction, weekly:("7d" displays at
bottom-left corner of LCD)
Step
Key
1
Press &MANUAL Into count
2
Press D+
3
Press
10. Check time: press " " to check whether the time is set correctly or not
Press "MANUAL" and then reset the time and week
Press "" to finish checking and setting, and the time will be display
afterwards
11. Press "MANUAL" to turn on or off at will, except 5
12. Press "D+" and "H+" for 3 seconds to turn off, but the setting will lost.
6
Technical information: -GWT 850ºC.
9
Product recycling:
-Contact the point of sale, local authorities or the manufacturer.
10
Information related to the WEEE II directive:
Do not throw them in the trash, recycle them.Treatment of electrical and electronic equipment at the end of its useful life.This product is marked
with the symbol to denote conformity with the European Directive 2012/19/EU on Waste Electrical and Electronic Equipment (WEEE II). This symbol on
the equipment or on its packaging indicates that the present product cannot be treated as normal household waste. It must be disposed in an electrical
and electronic collection point (free of charge).By ensuring that this equipment is disposed of correctly, you help prevent the potentially negative
consequences for the environment and human health that could result from improper disposal of it.
Mode d'emploi et de sécurité
1
Présentation:
●Count down: 1 sec - 99 min 59 sec
●Pulse: 1 sec - 59min 59 sec
●Load capacity: Resistive load: 16A/250V AC
8. Timing
8.1 Press and press D+ repeatedly go to today
8.2 Press and press H+/M+ to change hr/min
Programming
9. Having operated items mentioned above, please be sure to reset the ON and OFF according to the current time, press
"MANUAL" in order to display at the bottom line of the LCD
Setting 0sec-30sec
Confirm
Halogen Free
Lagging load: 8A/250V AC
Lamp load: 2000 W
4. PULSE setting:(" " displays at bottom - left corner of LCD).
Step
1
Press H+ & M+
2
Press &H+/M+
3
Press &MANUAL
4
Press
5
Press H+/M+
6
Press D+
7
Repeat step 2- 3
8
Press
9
Press H+&M+
*If need not 18 pulse press""key to the end.
6. Pause
Neither needn't the timer work nor delete the set program. You could just pressand "MANUAL" for 3.
Seconds at the same time to make the timer "AUTO OFF" permanently (only can access when "ON
AUTO"), in that case, the timer can not be changeover, "┌" displays at the bottom-left corner of LCD,
press and "MANUAL" to restore "AUTO OFF", and the timer turn to work normally.
13. Press "RESET" to reset, but the settings can not be restored
NOTE
●Time setting should according to the time sequence, couldn't be set crossly
●System with quit automatically if there's no operating within 10 seconds, and no
data is saved. It will quit when setting finished.
●Function 3,4,5, can not be used simultaneously
7
Product maintenance:
-Clean with a dry cloth.
-3-
off-Present time (ON OFF position). Auto
● Power reserve: 3 years (lithium battery)
● Ambient temperature: -10~+40ºC
Key
Into pulse setting
Set ting pulse time range 1 sec - 59min 59sec
Confirm pulse time range
Into setting 1 on time( display 1 on)
Setting on time
Select days of week. Same everyday, MO-FR,MO-SA,SA-SU,MO -WE,TH-
SA,MO WE FR, TU -TH-SA, different everyday.(If same everyday, not press
this key)
Setting 2 - 18 pulse
End
Exit pulse
8
ENGLISH
Programming
Safety and usage tips.
FRANÇAIS