Fuse Replacement; Uho-Hbps-10, -50, And Uho-Hps; Camera/Lens Wiring - Bosch UHI Serie Manual Del Usuario

Ocultar thumbs Ver también para UHI Serie:
Tabla de contenido

Publicidad

UHI/UHO Series
5.13

Fuse replacement

1.
2.
There is a spare fuse inside the housing.
6

UHO-HBPS-10, -50, and UHO-HPS-50

6.1

Camera/lens wiring

Installation for these models is in accordance with
Section 5 Installation, except as noted below.
CAUTION!
Use only 24 VAC power for UHO-HBPS-10 models. These
models have female connectors to prevent them from being
connected to the mating connector that is provided with UHO-
HPS-50 and UHO-HBPS-50 models that require 230 VAC. Ensure
that 230 VAC is not applied to the male mating connector.
All electrical power connections are made through the 4-pin
connector. Cable Requirements for the 4-pin connector:
6.0 mm (0.24 in) to 12.0 mm (0.47 in)
1.
Bosch Security Systems, Inc.
To replace a fuse, pull the top of the fuse holder.
Replace the fuse with a fuse that has the same current
rating. The fuse is a 5 mm x 20 mm slow blow breaking
capacity cartridge-type fuse.
Camera voltage
24 VAC
120 VAC
230 VAC
Cut the power cord on 230 VAC camera models, leaving
enough cable for connection to the terminal block. Strip no
less than 6 mm (0.25 in) and no more than 8 mm (0.31 in)
of insulation away from the wire. Be sure not to nick the
wires.
Installation Manual
UHO-HBPS-10, -50, and UHO-HPS-50 | en
Fuse rating
4 A, 250 VAC
2 A, 250 VAC
2 A, 250 VAC
F.01U.167.418 | 3.0 | 2010.04