ouTLET pRESSuRE GAuGE
The outlet pressure gauge (C) indi-
cates the air pressure available at the
outlet side of the regulator. This pres-
sure is controlled by the regulator and
is always less than or equal to the
tank pressure.
REGuLAToR
The regulator (D) controls the air pres-
sure shown on the outlet pressure
gauge. Turn regulator knob clockwise to increase pressure and
counterclockwise to decrease pressure.
DRAIn VALVE
The drain valve (H) is located at the base
of the air tank and is used to drain con-
densation at the end of each use. See
Draining Air Tank under Maintenance.
AIR CoMpRESSoR puMp
The pump compresses air into the air tank. Working air is not
available until the compressor has raised the air tank pressure
above that required at the air outlet.
MoToR oVERLoAD pRoTECToR
This motor has a manual thermal overload protector. If the
motor overheats for any reason, the overload protector will shut
off the motor. The motor must be allowed to cool down before
restarting. To restart:
1. Ensure the On/Off switch (A) is in the OFF position.
2. Allow the motor to cool.
3. Depress the reset button (E) on the motor.
SITE GLASS
B
C
The crank case (L) is full when the oil level
reaches the halfway point in the site glass.
D
oIL DIpSTICk
The oil dipstick (K) indicates the amount of
C
oil in the pump. Check pump oil daily, see
B
D
Compressor pump oil under Maintenance.
AIR InTAkE fILTER
E
The filter (M) is designed to clean air entering
the pump. To ensure the pump continually
receives a clean, cool, and dry air supply the filter must always be
clean and the filter intake must be free from obstructions.
INSTALLATION
Assembly
InSTALLInG HoSES
WARNING: Risk of unsafe operation.
H
Firmly grasp hose in hand when installing or
disconnecting to prevent hose whip.
1. Ensure regulated pressure gauge reads
2. Apply sealant tape to hose threads.
3. Assemble hose to air outlet (E). IMpoRTAnT: Do not assemble
noTE: Assembling quick connect bodies to air outlet (E) and quick
connect plugs to hose ends make connecting and disconnecting
hoses simple and easy. Quick connect bodies and plugs are
available for purchase from your local dealer or authorized
service center.
DISConnECTInG HoSES
WARNING: Risk of unsafe operation. Firmly grasp hose in hand
when installing or disconnecting to prevent hose whip.
12
0 PSI (0 kPa).
splitters directly to the air outlet (E).
L
M
K