Operating Instructions; Maintenance - Sanborn LA1983012 Manual Del Operador - Manual De Piezas

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

DAILY START-UP
1.
Turn the pressure switch to the OFF position (see C).
2.
Close the tank petcock (see F). Turn in the clockwise
direction.
3.
Plug in the power cord.
WARNING:
by the electric motor and the pump. To prevent
burns or other injuries, DO NOT touch the
compressor while it is running. Allow it to cool
before handling or servicing. Keep children away
from the compressor at all times.
4.
Turn the pressure switch to the AUTO position (see D).
5.
Adjust the regulator to the working pressure of the tool.
NOTE: To adjust pressure setting, turn the knob clockwise to
increase pressure, and counterclockwise to decrease pressure.
WARNING:
turn the knob counterclockwise past
the desired setting, then turn clockwise to reach the
desired pressure. Do not exceed operating pressure
of the tool or accessory being used.
SHUTDOWN
1.
Turn the pressure switch to the OFF position (see C).
2.
Unplug the power cord.
3.
Reduce pressure in the tank through the outlet hose. You
can also pull the tank safety valve ring (see G) and keep it
open to relieve pressure in the tank.
4.
Open the petcock (see E) to allow moisture to drain from
the tank.

MAINTENANCE

WARNING:
To avoid personal injury, always shut off
and unplug the compressor and relieve all air pressure
from the system before performing any service on the air
compressor.
Regular maintenance will ensure trouble–free operation.
Your electric powered air compressor represents high–quality
engineering and construction; however, even high–quality
machinery requires periodic maintenance. The items listed below
should be inspected on a regular basis
DRAINING THE TANK
Drain the moisture from the tank (for instructions, see
"Shutdown" in the operating instructions section).
WARNING:
the tank. To prevent corrosion of the tank from the
inside, this moisture must be drained at the end of
every workday. Wear protective eyewear.
NOTE: In cold climates, drain the tank after each use to reduce
problems with freezing of water condensation.
200-2929

OPERATING INSTRUCTIONS

High temperatures are generated
When adjusting from a higher to
a
lower pressure,
Condensation will accumulate in
propel debris that may cause eye injury. Wear safety
goggles when opening petcock.
G
OPEN
E
MAINTENANCE
TO REPLACE OR CLEAN CHECK VALVE
WARNING:
automatically. ALWAYS shut off the compressor,
remove the plug from the outlet, and bleed all
pressure from the system before servicing the
compressor, and when the compressor is not in use.
Do not use the unit with the shrouds or belt guard
removed. Serious injury could occur from contact
with moving parts.
1.
Turn air compressor off, remove the power cord from the
outlet or lock out the
power supply and
relieve all the air
pressure from the tank
(refer to "Shutdown" in
Operating Instructions).
Make sure the
compressor has cooled
down before servicing.
2.
Using the appropriately
sized wrench, loosen the
compression nut
(A) on the check valve
7 - ENG
CAUTION:
Escaping air and moisture can
CLOSE
F
RISK OF INJURY. This unit starts
Fig. 6

Publicidad

Tabla de contenido
loading

Tabla de contenido