4) Release the locking screw at the lens bracket and
unscrew the lens.
5) Screw the new lens onto the camera. Establish the
plug connection to the PCB again, apply the operat-
ing voltage and adjust the camera to the monitoring
area. Carefully screw the lens so far in and out until
the picture is clear and then fix it by tightening the
screw.
6) Build in the PCB again and assemble the housing.
When assembling, take care that the camera mod-
ule as well as the "eyeball" are inserted the right
way round.
7 Specifications
Image sensor: . . . . . . . . . CCD chip, 8.5 mm (
Synchronization: . . . . . . . . CCIR, hor. 15 625 Hz,
Number of pixels: . . . . . . . hor. 500 x vert. 582
Resolution: . . . . . . . . . . . . 400 lines
Fixed focus lenses: . . . . . 1 : 2.0/3.6 mm,
Minimum illumination: . . . . 0.1 lux
S/N ratio: . . . . . . . . . . . . . > 45 dB
Video outputs: . . . . . . . . . 1 Vpp/75 Ω, BNC
Ambient temperature: . . . . -10 °C to +50 °C
Power supply: . . . . . . . . . 12 V /500 mA
Dimensions
of the camera ball: . . . . . . Ø 200 mm x 360 mm
Weight of the camera ball: 720 g
According to the manufacturer.