6 von 16
Parts included
Quantity Mat. no.
Designation
1
Steam/foam vent adapter
1
Cold-water hose
1
Hot-water hose
2
Raised-head screw, 4 x 15mm
1
(Sponge-rubber) seal, 0.5m
Danger due to incorrectly carried out service and repair work
WARNING
Danger due to incorrectly carried out service and repair work.
There is a risk of serious damage, injury and even death if service and repair work is carried out incorrectly.
A
Service and repair work should only be carried out by a suitably qualified electrician with specialist training,
knowledge and experience.
A
All appropriate safety regulations must be taken into account.
A
Read the technical service documentation (TSD) before starting service work.
Risk of cuts
CAUTION
Components are sharp.
Risk of cuts.
A
Protective gloves should be worn and the edge protection, mat. no. 05057680, should be used.
Steam and foam venting kit BWS01
A
Close the water supply valve.
A
If desired, the existing water intake hoses can be replaced with intake hoses with angled adapters.
A
Attach the sponge-rubber seal (1) around the edge of the vent; see Fig. 1.
A
Stick the steam/foam adapter on the suds container vent; see Fig. 2.
A
Drill a 2.5mm hole (1) on each side of the steam/foam adapter; see Fig. 2.
A
Secure the steam/foam adapter with two of the provided 4 x 15mm screws.
A
If necessary, connect the steam/foam adapter to an onsite drain or vent using high-temperature heat pipe.
A
Open the water supply valve.
A
Carry out a functional check.
en-US
el
Οδηγίες συναρμολόγησης σωλήνα εξόδου υδρατμών και αφρού BWS01
Βασική πληροφορία: Με τον σωλήνα εξόδου υδρατμών και αφρού BWS01 είναι δυνατή η ελεγχόμενη εξαγωγή του
αφρού από το σύστημα εξαερισμού του κάδου.
07.06.2018
Diese Unterlagen dürfen ohne unsere Genehmigung weder vervielfältigt noch Dritten zugänglich gemacht werden. Eigentumsrechte vorbehalten.
Umbau- und Montageanweisung
M.-Nr. 06779732