PRODUCT DATA SHEETS
Base Grille Water
Filtration
System
Model T2WG2L/T2RFWG2
Capacity 200 Gallons (758 Liters)
Model T2WG2/T2RFWG2
Capacity 200 Gallons (758 Liters)
Tested and certified by NSF International against NSF/ANSI Standard
42 for the reduction of Chlorine Taste and Odor, Particulate Class I1";
and against NSF/ANSI Standard 53 for the reduction of Mercury,
Benzene, Toxaphene, O-dichlorobenzene,
and Carbofuran.
This system has been tested according to NSF/ANS142/53
for the reduction of the substances
listed below. The concentration
of
the indicated substances
in water entering the system was reduced to a concentration
less than or equal to the permissible limit for
water leaving the system, as specified in NSF/ANSI 42/53.
Substance
Reduction
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Average %
Aesthetic
Effects
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Chlorine Taste/Odor
50% reduction
2.0182 mg/L
2.0 mg/L _+10%
0.06 mg/L **
0.0536 mg/L
97.03
97.34
Particulate Class II*
85% reduction
1333333 #/mL
At east 10,000 part c es/mL 6600 #/mL
2325 #/mL
99.51
99.83
Contaminant
NSF Reduction
Average
Influent Challenge
Maximum
Average
Minimum %
Average %
Reduction
Requirements
Influent
Concentration
Effluent
Effluent
Reduction
Reduction
Lead: @ pH 6.5***
0.010 mg/L
0.1533 mg/L
0.15 mg/L _+10%
0.0005 mg/L
0.0005 mg/L
99.67
99.67
Lead: @ pH 8.5***
0.010 mg/L
0.1400 mg/L
0.15 mg/L _+10%
0.0007 mg/L
0.0006 mg/L
99.50
99.57
Mercury: @ pH 6.5
0.002 mg/L
0.0058 mg/L
0.006 mg/L _+10%
0.0002 mg/L
0.0002 mg/L
96.54
96.54
Mercury: @ pH 8.5
0.002 mg/L
0.0059 mg/L
0.006 mg/L _+10%
0.0005 mg/L
0.0003 mg/L
91.57
94.92
Benzene
0.005 mg/L
0.0154 mg/L
0.015 mg/L _+10%
0.0012 mg/L
0.0006 mg/L
92.22
96.34
O-Dichlorobenzene
0.6 mg/L
1.7571 mg/L
1.8 mg/L _+10%
0.0250 mg/L
0.0066 mg/L
98.58
99.63
Toxaphene
0.003 mg/L
0.015 mg/L
0.015 mg/L _+10%
0.001 mg/L
0.001 mg/L
93.33
93.33
Carbofuran
0.04 mg/L
0.0819 mg/L
0.08 mg/L _+10%
0.0400 mg/L
0.0213 mg/L
51.13
74.00
Test Parameters: pH = 7.5 _+0.5 unless otherwise noted. Flow = 0.85 gpm (3.2 Lpm). Pressure =
Temp. = 68°F to 71.6°F (20°C to 22°C).
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Use replacement cartridge T2RFWG2, part #4396841.
In Canada, use replacement cartridge T2RFWG2, part
#4396841 B. 2006 suggested retail price of $39.99 U.S.A./
$49.99 Canada. Prices are subject to change without notice.
Model T2WG2L: Style 1 - Press FILTER to check the status
of your water filter. If the filter indicator light is yellow, order a
new filter. If the filter indicator light is red, it is recommended
that you replace the filter.
Style 2 - When the filter indicator reads 10%, order a new
filter. When the filter indicator reads 0%, it is recommended
that you replace the filter.
Model T2WG2: Change the water filter cartridge every
6 months depending upon your usage. If the water flow to the
water dispenser or ice maker decreases noticeably before
6 months have passed, replace the water filter cartridge more
often.
These contaminants
are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
60 psig (413.7 kPa).
Do not use with water that is microbiologically
unsafe or of
unknown quality without adequate disinfection before or after
the system.
Refer to the "Assistance or Service" section for the
Manufacturer's
name, address and telephone number.
Refer to the "Warranty" section for the Manufacturer's
limited
warranty.
Application Guidelines/Water
Supply Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8°C)
Service Flow Rate
0.85 gpm (3.2 Lpm) @ 60 psi
The product is for cold water use only.
*Class II particle size: 1 um to <5 um
**Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
***Compliant
for Lead reduction requirements
under NSF/ANSl Standard 53 as tested by Pace Analytical
Services, Inc.
(R_ NSF is a registered trademark
of NSF International.
13