2. INSTALLATION
2.1 INSTALLATION INSTRUCTIONS
Attention! The appliance must be installed on the solid surfaces like concrete, wood or
metal etc. Never install on flammable surfaces! (Plastics, nylon vinyl etc.)
Follow figure 1, 2 and 3 on page 2-3 for mounting and safety distances.
• If your appliance is marked with IP34 or IPX4 or higher it can be mounted in unprotected
outdoor areas. See the label on the back of the product for the "IP" mark.
• Drill four holes on the wall to the place where the unit will be installed, with the distances.
• Insert the wall plugs (if needed), supplied with the unit, into the holes.
• Mount two of the L shaped legs on the wall using the screws supplied with the unit.
Mount the other L legs on the unit using the four screws and the small wrench as shown
in (corresponding nuts are already built in on the body of the unit) pictire 1 on page 2.
• Mount and fix the L shape legs on the wall and on the unit respectively, using the bolts
and nuts and the washers and tighten.
• Depending on the area to be heated the angle of the unit can be adjusted between 0-40
degrees by the help of M8 Bakelite head bolt and nut fixture.
• The heater can be mounted on the ceiling or wall.
Warning! In case of an installation on the ceiling the heater may discolour the surface
depending on the surface material.
• Before operating the unit joints should be checked once again.
2.2 INSTALLATION INSTRUCTIONS POSITION + DISTANCE
For minimum safety distances in case of horizontal installations. For minimum distances
from coverage area and other objects please see figure 2 on page 2.
2.3 INSTALLATION INSTRUCTIONS WITH RIGHT AND WRONG POSITIONS
DIRECT YOUR HEATER TOWARDS THE MOST APPROPRIATE ANGLE
See figure 3 on page 3.
Do not let the light go out through the window, glasses etc. as the heater primarily heats
the locations onto which its light falls
Models without "X" in the model description can ONLY be mounted HORIZONTAL!
Maximum tilt / angle is 5 degrees otherwise the heater will be damaged in a short time.
Models with "X" in the model description like "XT/XR and RX" versions can be mounted in
any direction. The power cord outlet shall be in the lowest point when used in
vertically or tilted angle.
2.4 CEILING OR VERTICAL MOUNTING
ATTENTION!
When mounting "R" or "XR" models face down (ceiling) or "XR" models in the vertical
direction, the built-in tilt switch has to be de-activated.
To de-activate the electronic tilt switch follow step 1-4;
1.
Unplug the power cord.
2.
Press and hold the two buttons (see figure F4 on page 3) at the same time.
3.
Plug in the power cord (while keeping the two buttons pressed in).
4.
Wait for 3-5 seconds until a "beep" sound.
The tilt switch is now de-activated, and the heater can be mounted face down or vertically.
To activate the tilt switch, repeat step 1-4.
7