Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

1 - Welding settings selection
SYNERGIC or MANUAL
2 - Welding process selection
PULSE or STANDARD
3 - Selection of the metal (synergic welding settings)
Each material is associated with a different recommendation for gas and
diameter of wire.
The different materials available are:
- Fe - Steel with Ar+CO2 gas (18%) or CO2 gas (only standard)
- AlMg5 - Aluminium with Ar gas
- SS – Stainless steel with Ar+CO² (2%)
- CuSi – Cu Si 3 with Ar gas
- CuAl – Cu Al 8 with Ar gas
- AlSi 5 and AlSi 12 with Ar gas
For optimal use, it is recommended to use the wire and gas recommended for the selected material.
These synergies modes can be updated by using the SD card (see SD section)
4 - Arc length setting (synergic)
Allows the adjustment of the arc length between -9 -> +9 (synergic)
5 - Metal thickness setting (synergic)
To set up the thickness of the metal between 0.6 to 10 mm (synergic)
6 - Thermal protection light
Indicates that the thermal protection has been activated after intensive use (the machine will turn off for a few minutes)
SETTING UP THE PULSEMIG:
IN « MANUAL » MODE
• Advice
The wire speed adjustment is often determined « by the noise »: the arc must be stable and have a
low crackling.
If the speed is too low, the arc is not continuous.
If the speed is too high, the arc crackles and the wire pushes back the torch.
USING THE « SYNERGIC » INTERFACE
The operator may choose between the 2 levels of settings available on the machine depending on his professional expe-
rience: EASY (simplified synergic) and PRO (fully synergic).

PRO INTERFACE

24
PULSEMIG 300-T2
• Manual mode settings:
In Manual mode, the speed of the wire and the voltage for the welding can be
adjusted using potentiometers A and B.
- Display in Manual Mode (the mode selected will be displayed at the bottom of
the screen).
Before welding:
The speed of the wire is permanently displayed on screen.
During Welding:
The average welding voltage and intensity are displayed.
These values stay on the screen until you change the parameters.
The top part is used to select the wire diameter, the gas-metal com-
bination, the welding mode (standard, pulse, manual) and the trigger
mode (2T, 4T).
The icon
allows you to enter the secondary menu of PRO mode.
EN

Publicidad

Tabla de contenido
loading