The operating mode of "P.P. Push button" and of the transmitter are selected.
PP
On: Operation : OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Forewarning flashing light enabled or disabled.
On: enabled forewarning flashing light. The flashing light is activated 3 s before
PRE
the starting of the motor.
Off: disabled forewarning flashing light.
The Service Man function is enabled or disabled.
On: Service Man operation. The OPEN and CLOSE push-buttons should
HTR
be kept pressed during the entire operation. PP input and transmitters are
disabled.
Off: Automatic operation.
During the TCA time, the blinker is enabled or disabled.
LTCA
On: Enables blinker.
Off: Disables blinker.
The OPEN Input mode is selected
On: OPEN Input, with WATCH function.
CLOC
To be used to connect the timer for timed opening/closing. (CLOSED contact-
open gate, Open contact, normal operation).
Off: OPEN Input, with OPEN function
The code programmable transmitters is enabled or disabled.
On: Radio receiver enabled only for rolling-code transmitters.
CVAR
Off: Receiver enabled for rolling-code and programmable code transmitters
(self-learning and Dip Switch).
The service light function is enabled or disabled on the SCA output.
On: The output is provided with service light function. At each operation, the
output supplies 24Vac for the time preset with TLS parameter. TLS time count
serL
starts with motor stop. Use an auxiliary relay to control the light.
Off: The output is provided with SCA function, open gate light: switched off
light with closed gate, flashing light with moving gate, switched on light with
open gate. See wire diagram.
Check of OPEN and CLOSE relays is enabled or.
On: Check enabled: if one of the 2 relays is faulty, the motor does not start and
TREL
the error message "ERR2" is displayed.
Off: no check to relays is carried out.
Soft start is enabled or disabled.
On: Starting is performed at reduced speed for 2s and then movement is re-
SOFT
stored to normal speed.
Off: Soft start is disabled.
The PHOT Input operating mode is selected.
On: PHOT Input is activated during closure only.
During closure: the opening of the contact causes the motor stop and the
immediate movement reversion (open).
PH C
Off: PHOT Input is activated in both opening and closing.
In the opening phase: when opened, the contact causes the motor stop. When
the photocell is released, the motor restarts in the opening phase.
In the closing phase: when opened, the contact causes the motor stop. When
the photocell is released, the motor inverts its movement direction (open).
The movement reversion during opening after the activation of the anti-crash
device (amperometric sensor) is enabled or disabled.
On: enabled reversion. The amperometric sensor activation causes the
INvA
movement reversion.
Off: disabled reversion. The amperometric sensor activation causes the
movement stop.
Enables or disables door stop before the opening mechanical stop
ON: The control unit stops the door around 5 cm before the mechanical stop.
SASO
In this way stop is progressive and without vibrations.
OFF: The control unit stops the door on the opening mechanical stop
(OFF)