2.4. Assembly and disassembly of the covers
A Torx T20 screwdriver and a 4 mm Allen wrench are needed to assemble and disassemble the covers.
9. Disassemble the top cover. Remove the screws located at the rear and pull the cover upwards.
10. Disassemble the front cover. Remove the screws located at the upper part and pull the cover upwards.
11. Disassemble the side covers. Remove the fastening screws and remove the cover.
During cover disassembly, take care to remove the control panel cable without damaging it.
NOTE
2.5. Recommended positioning
Choose a dry place where there is no risk of frost. Avoid installation against bedroom walls or walls of other rooms where noise
emissions can be annoying. If possible, install the heat pump with the rear part pointed toward an exterior wall. Avoid installation
near a corner, since this can amplify noise emission levels.
The heat pump should be installed on a stable base that can support the total weight of the equipment and the operating fluids in
its interior. Use the adjustable legs to compensate for possible irregularities on the supporting surface. Use the eyebolts provided
with the heat pump to move the equipment to its final destination.
Figure 1.3. Disassembly of the covers from the ecoGEO HP models.
Figure 1.4. Positioning and levelling the heat pump.
Installer manual ecoGEO HP
31