To order these accessories, call 1-800-525-2579.
 Brass Nozzle ........................................................................................................................................ Model No. PMC080
 Nozzle Cleaner .................................................................................................................................. Model No. PMCC008
 1/2 in. PVC Coupler with Nozzle ......................................................................................................... Model No. PMC160
 1/2 in. PVC Hose Adaptor ................................................................................................................... Model No. PMC170
 4 in. Flexible Nozzle Extension (5 pack) ....................................................................................... Model No. PMC005PNE
 1/2 in. Hanging Mount (5 pack) ..................................................................................................... Model No. PMC400HM
WARNING:
Current attachments and accessories available for use with this product are listed above. Do not use any attachments
or accessories not recommended by the manufacturer of this product. The use of attachments or accessories not
recommended can result in serious personal injury.
PROBLEM
Leak at nozzle, threaded hole, or
coupler
Misting kit will not spray
Loss of pressure
Water stuck in misting tube assembly
after use
NOTE: ILLUSTRATIONS START ON PAGE 9 AFTER FRENCH

ACCESSORIES

TROUBLESHOOTING

POSSIBLE CAUSE
Nozzles were installed improperly.
Nozzles clogged or dirty.
A water-tight seal was not created
when assembling the coupler and PVC
misting tubes.
Water faucet is off.
T-filter is clogged.
Nozzles clogged or dirty.
T-filter is clogged.
Defective drain valve.
Drain valve not connected to lowest
point in system.
AND SPANISH LANGUAGE SECTIONS.
8 — English
SOLUTION
Reinstall nozzles and tighten securely.
Clean nozzles.
If possible, re-cement the leaking sec-
tion. If not possible, the leaking section
must be removed and replaced.
Turn hose faucet completely on.
Follow instructions for cleaning strainer
in Maintenance.
Clean nozzles.
Follow instructions for cleaning strainer
in Maintenance.
Replace drain valve.
Move the drain valve to the lowest
position available.