Technical Data; Ambient Conditions; Operation - Garant mLevel Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

14. Technical data

14.1.

Ambient conditions

The recommendations listed below should be complied with as closely as
possible, since they ensure consistent performance by the device coupled
with the minimum requirement for maintenance.
14.2.

Operation

Temperature: +10 °C to +40°
Duty cycle: 10% (S3); 1 min ON, 9 min OFF
Environment: for use only in dry indoor areas
item
92 0001
92 0003
92 0011
92 0013
92 0021
92 0023
*load evenly distributed
Mechanical and electrical data for each lift column.
max. load
max. lifting force
max. lateral load
max. lifting speed
Drive
max. load*
[kg]
250
250
250
250
250
250
per column 1600 N.
longitudinally:
1200 Nm static
500 Nm dynamic
transversely:
450 Nm static
255 Nm dynamic
9 mm/s at 24 V unloaded.
Internally mounted DC drive,
integral limit switches and 2
Hall sensors.
www.hoffmann-group.com
Height adjustment
range
[mm]
750 – 1000
750 – 1000
700 – 1000
700 – 1000
700 – 1000
700 – 1000
DE
DE
EN
FR
FR
IT
IT
ES
ES
23

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Elevel

Tabla de contenido