8 Technical Specifications
ACTOR ADX 112 A
Connections:
Line In:
Input:
Input impedance:
Sensitivity:
Max. input level:
Frequency response +/- 3dB:1)
Axial sensitivity 1W@1m:2)
Maximum SPL @1m: 2)
Mid/high-range amplifier:
Active protective circuits:
Midrange speaker:
Tweeter/ driver:
Directivity:
Crossover frequency:
Pole mount:
Rigging points:
Accessories:
Dimensions (WxDxH):
Weight:
General electrical data:
Protection class 1 (protectively earthed)
Max. current consumption:
Max. power consumption:
Mains voltage range:
Ambient temperature range during operation:
Internal fuses:
1) Via active crossover
2) All measurements taken under half-space conditions
1x XLR Line In
1x XLR Line Through
1x XLR Subwoofer Output
XLR female (pin 1= Ground; 2= +, 3= -)
Electronically balanced & floating
20 k ohms
Switchable from –10 dB to 0 dB (= +4 dBu)
+22 dBu
80 Hz – 19 kHz full-range mode
130 Hz – 19 kHz Stop-only mode
106 dB
129 dB @ 10% THD
1x 600 W RMS/ Class D
DDO™ Controller Multiband Limiter, Subsonic Filter
12"
1.4"
60° x 40° CD horn
950 Hz, 12 dB/octave
HK AUDIO DuoTilt™, 36 mm, 7.5°, 15°
4 M10 threaded bushings for attaching an optional
rigging bracket
ACTOR DX Tilt-Unit, 7.5°, 15°
39 cm x 65 cm x 42 cm
15 1/4" x 25 5/8" x 16 1/2"
32 kg/ 70.6 lbs.
13 A (220 - 240 V)
8 A (100 - 120 V)
1000 W
+/- 10%
-10° C to +35° C
T8A