2 Applications

This LED spotlight is used for illumination, e . g .
on stage, in discotheques and function rooms .
Twelve 10 W LEDs are used as a light source .
Each LED consists of six individual LEDs lighting
in the colours red, green, blue, white, amber and
UV . When these colours are mixed, the range of
colours is much wider than that of basic RGB
LEDs .
The spotlight is designed for control via
a DMX light controller (optional DMX control
channels: 3, 6, 8, 10 or 13), but it can also be
operated independently without a controller .
The ODP-120/6COL is weatherproof (IP 65) and
therefore also suited for outdoor applications .
3 Setting the Spotlight into
Operation

3.1 Installation

Always position the spotlight in such a way
to ensure sufficient air circulation during op-
eration . Never cover the cooling fins of the
housing .
Always keep a minimum distance of 50 cm to
the illuminated object .
WARNING Always install the spotlight safely
and expertly . When the spot-
light is installed at a place where
people may walk or sit under it,
additionally secure it (e . g . via a safety rope at
the mounting bracket; fasten the safety rope in
such a way that the maximum falling distance
of the spotlight will not exceed 20 cm .
1) Install the spotlight via its mounting brackets,
e . g . with a stable mounting screw or a sup-
port for lighting units (C hook) on a cross bar .
To align the spotlight, release the two
lateral locking screws . Adjust the desired in-
clination and fasten the screws again .
2) Alternatively, use the mounting brackets to
set up the spotlight on its own (refer to Fig . 1) .

3.2 Power supply

Connect the mains cable (POWER IN) of the
spotlight to a mains socket (230 V~/ 50 Hz) . Thus,
the unit is switched on .
WARNING
To prevent damage to your eyes,
never look directly into the light
source for any length of time .
Please note that fast changes in lighting may
trigger epileptic seizures with photosensitive
persons or persons with epilepsy!
If the cable POWER IN is not connected to the
mains plug, connect plug A to inline jack B (refer
to Fig . 2):
POWER IN
A
B
Fig. 2 Mains connection
CAUTION! The cable POWER OUT carries mains
voltage . If no further unit is connected to the ca-
bles POWER OUT and DMX OUT, always screw the
protective covers supplied onto the inline jacks .
3.2.1 Power supply

of multiple ODP-120/6COL spotlights

If multiple ODP-120/6COL are used, the spot-
lights can be interconnected for power supply .
For the time being, do not yet connect the first
unit to a mains socket .
1) Use the inline jack of the cable POWER OUT
to connect the first unit to the plug (A) of the
cable POWER IN of the second unit . Proceed
in the same way to connect the second unit
to the third one etc . until all units have been
connected in a chain .
If the mains connection cables between
the spotlights are too short, use suitable ex-
tension cables, e . g .
ODP-34AC (2 m) or ODP-34AC/10 (10 m) .
CAUTION! To reduce the risk of cable fire
caused by overload, the total current in the
connection cables must not exceed 10 A .
Therefore, do not interconnect more than
23 ODP-120/6COL spotlights .
2) On the last spotlight, screw the protective
cover supplied onto the inline jack of the cable
POWER OUT . The cable carries mains voltage!
3) Connect the mains plug of the first spotlight
to a mains socket (230 V~/50 Hz) .
230V~