"Continuous" operation mode

In continuous operation mode, the device dehumidi-
fies the air constantly, regardless of the humidity in
the air.
To start continuous operation mode, set the rotary
switch (14) to "Max.".

Automatic defrost

If the room temperature is below 11 °C, the evapora-
tor becomes covered in frost during dehumidification.
The device then carries out an automatic defrost. The
duration of the defrost can vary.
• Do not turn off the device during the automatic de-
frost. Do not remove the mains plug from the
mains socket.
B - 11

Shut down procedure

1. Switch off the device at the mains switch (see
"Operating elements" chapter).
2. Depending on the model, proceed as follows to
remove condensation from the device:
– Remove the condensation drain hose and any
residual fluid from it.
– Empty the optional condensate pump by press-
ing the key for draining residual water from the
condensate pump.
3. Do not touch the mains plug with wet or damp
hands.
4. Remove the mains plug from the mains socket.
5. Clean the device, and especially the air filter,
according to the "Maintenance" chapter.
6. Store the device according to the "Storage" chap-
ter.
Operating Manual – Dehumidifier TTK 655 S