7. Starting, operation
Specifications
Model ECO-1
Pressure ranges
bar
Over pressure safety
bar
Pressure ranges
bar
Messbereich
bar
Over pressure safety
bar
Burst pressure
bar
{Absolute pressure: 0 ... 1 bar abs to 0 ... 16 bar abs}
Materials
Wetted parts
Case
Internal transmission fluid
1)
Not for models with pressure ranges > 16 bar.
1)
Power supply U
U
in VDC
B
B
Signal output and
R
in Ohm
A
maximum ohmic load R
A
Response time (10 ... 90 %)
ms
Dielectric strength
VDC
2)
Use NEC Class 02 power supply (low voltage and low current max. 100 VA even
under fault conditions)
Accuracy
% of span
3)
Including non-linearity, hysteresis, zero point and full scale error (corresponds to
error of measurement per IEC 61298-2).
Adjusted in vertical mounting position with lower pressure connection.
10
WIKA Operating instructions/Betriebsanleitung/Mode d'emploi/Instrucciones de servicio
1
1.6
2.5
4
6
10
5
10
10
17
35
35
6
12
12
20.5
42
42
40
60
100
160
250
400
80
120
200
320
500
800
200
300
500
800
1250
1300
Stainless steel
Stainless steel
Synthetic oil
≤ 30 (14 ... 30 with signal output 0 ... 10 V, 1 ... 6 V)
10 < U
B
≤ (U
4 ... 20 mA, 2-wire
R
– 10 V) / 0.02 A
A
B
0 ... 10 V, 3-wire
R
> 10000
A
1 ... 5 V, 3-wire
R
> 5000
A
1 ... 6 V, 3-wire
R
> 6000
A
≤ 5 (≤ 10 ms at medium temperatures below -30 °C for pressure
ranges up to 16 bar)
500
2)
≤ 0.5
(BFSL)
≤ 1.0
3)
GB
7. Starting, operation
Specifications
16
25
Non-linearity
50
50
Non-repeatability
80
80
1-year stability
Permissible temperature of
600
1000
Medium
1200
1500
4)
1800
3000
Ambience
4)
Storage
4)
Compensated temp range
Temperature coefficients within
compensated temp range
Mean TC of zero
Mean TC of range
CE- conformitiy
Pressure equipment directive
EMC directive
Wiring protection
Weight
{ } Items in curved brackets are optional extras for additional price.
When designing your plant, take into account that the stated values (e.g.burst pressure,
over pressure safety) apply depending on the material, thread and sealing element used.
ECO-1
WIKA Operating instructions/Betriebsanleitung/Mode d'emploi/Instrucciones de servicio ECO-1
Model ECO-1
% of span
≤ 0.4
(BFSL) according to IEC 61298-2
≤ 0.1
% of span
% of span
≤ 0.3
(at reference conditions)
-40 ... +100 °C
-30 ... +80 °C
-30 ... +100 °C
Also complies with EN 50178, Tab. 7, Operation (C) 4K4H, Storage (D) 1K4,
4)
Transport (E) 2K3
0 ... +80 °C
% of span
≤ 0.4 / 10 K
≤ 0.3 / 10 K
% of span
97/23/EC
2004/108/EC, EN 61 326 Emission (Group 1, Class B) and
Immunity (industrial locations)
Protected against reverse polarity and short circuiting on the instru-
ment side
kg
Approx. 0.15
GB
-40 ... +212 °F
-22 ... +176 °F
-22 ... +212 °F
+32 ... 176 °F
11