3. Specifications
3. Specifications
Specifications
Measuring ranges
Overpressure limit
Burst pressure
Measuring ranges
Overpressure limit
Burst pressure
Material
Wetted parts
Model D-10-7
■
Model D-11-7
■
Case
Internal transmission fluid
Power supply U
B
Output signal
Power consumption
Sensor services
Terminating resistor
Internal measuring rate
Warming-up period
Insulation voltage
4)
Accuracy
Non-linearity
WIKA operating instructions pressure transmitter model D-1x-7
Models D-1x-7
bar
0.25 0.4
bar
2
bar
2.4
bar
25
bar
50
bar
96
{Vacuum, gauge pressure, +/-, and absolute pressure are available}
(for other materials see WIKA diaphragm seals product range)
Stainless steel (with measuring range > 25 bar additionally Elgiloy
Stainless steel {Hastelloy}; O-ring: NBR {FPM/FKM or EPDM}
Stainless steel
Synthetic oil {halocarbon oil for oxygen applications}; {listed by FDA for
3)
food industry}
10 ... 30 V
DC
Profibus
W
1.7
2-byte error coding for sensor error or failure of electronics, min./max.
value upper deviation temperature + pressure
Internal terminating resistor can be activated via integrated DIP switch
Hz
≤ 100
min
< 10
DC
500 V
% of span
≤ 0.25 {0.10} in the range 0 ... +50 °C
% of span
≤ 0.04 (BFSL) per IEC 61298-2
0.6
1
1.6
2
4
5
10
2.4
4.8
6
12
40
60
100
160
80
120
200
320
400
800
800
1,000 1,200 1,700
DP protocol per EN 50170 / DIN 19245
®
2.5
4
6
10
10
17
35
35
12
20.5
42
42
250
400
600
1,000
500
800
1,200
1,500
2)
2)
2,400
3,000
GB
16
80
96
1)
)
®
9