Installation Instructions
combinations. This is practical when there is more than 1 remote/receiver pair operating locally or in the
same room.
Note: To access the receiver DIP switches, remove the DIP switch cover.
Fig. 1 Remote battery compartment
Installation directions
-
For your safety: Power to the circuit must be disconnected or switched off.
-
Household power can cause SERIOUS INJURY or DEATH.
Wiring must meet all local and national electrical wiring codes.
-
MAKING THE ELECTRICAL CONNECTIONS
CONNECTION METHOD VIA LOOMS – Compatible with most LUCCI brand (AC motor) Ceiling Fans.
Connecting the remote receiver to the fan with LUCCI loom connectors. (see Fig. 3-a)
1) Disconnect electrical power from the working circuit.
2) Remove the ceiling fan canopy cover from the mounting bracket.
3) Disconnect existing wiring from the supply at the ceiling.
4) Connect the supply EARTHING wire to the "
5) Connect the supply LIVE to the "L" terminal of the terminal block.
6) Connect the supply NEUTRAL to the "N" terminal of the terminal block.
7) Connect the connector (1) from the fan mounting bracket to the input connector (1) from the receiver.
3 | P a g e
WARNING – HIGH VOLTAGE
BEFORE CONNECTING THE RECEIVER & CHANGE CODES
Fig. 2 Receiver DIP switch
" Terminal of the terminal block