Operating the air conditioner

1.2.11 FAILURES

When any failure occurs in the air conditioning system, the display will show a
message as shown below
Important: Whenever a failure to the air conditioner system is identified, the
vehicle must be sent to a Spheros authorixed sevice station.

1.2.11.1 CONTROLLER GL-W163 ALARM FAILURES

FAILURE
Pressure Switch failure
Temperature sensor open
Temperature sensor in shock
Alternator failure
1 - If any failures occurs to the pressure switch, the display will show the massage
(HA) and de system will shut the compressor off. The controller will wait for 3 minutes
before turning the compressor again, once the failure is corrected.
2 - As the system operates according to the internal temperature, the controller has
two failure codes to monitor the temperature sensor:
a) If the temperature sensor is open, the display will show (OP)
b) If the temperature sensor is in shock, the display will show (SC)
3 - This controller has a paremeter to monitoring the alternator. In case of failure in the
alternator the display will show (AL).
DESCRIPTION
1.2.11.2 CONTROLLER GL-210 ALARM FAILURES
FAILURES
Alternator failure
Air return sensor failure
Duct sensor failure
External sensor failure
Pressure Switch failure
Communication failure
Valve connection failure
1 - This controller has a parameter to monitoring the alternator. In case of failure in the
alternator the display will show (AL), however the controller outlets will continue to be
on
2 - Should there be a failure in the air return sensor, the display will show (FI).
3 - Should there be a failure in the air duct sensor, the display will show (F3).
4 - Should there be a failure in the external sensor, the display will show (F5).
5 - Should a pressure failure occurs, the display will show the massage (FP) and the
system will shut the compressor off. The system will wait for 3 minutes before turning
on the compresor again, once the failure is corrected.
6 - Should there be a communication failure the display will show (FC) and only the
cooling mode will work.
7 - Should the heating system valve connection fail, the display will show (EI).
DESCRIPTION
24