1-5. INSTALLATION DIAGRAM

Open as a rule
More than 500 mm
(19-11/16 in.) if the
front and both sides
are open
More than
100 mm
(3-15/16 in.)
Open as a rule
More than 500 mm (19-11/16 in.) if the
back, both sides and top are open
200 (7-7/8)
Air inlet
2 - 12 (15/32) × 36 (1-31/32) oval holes
(Base bolt M10)
En-3
After the leak test, apply insulat-
ing material tightly so that there is
no gap.
When the piping is to be at-
tached to a wall containing metals
(tin plated) or metal netting, use
a chemically treated wooden
piece 20 mm (25/32 in.) or thicker
between the wall and the piping
or wrap 7 to 8 turns of insulation
vinyl tape around the piping.
To use existing piping, perform
COOL operation for 30 minutes
and pump down before removing
the old air conditioner. Remake
flare according to the dimension
for new refrigerant.
More than 100 mm (3-15/16 in.)
More than 200 mm (7-7/8 in.)
if there are obstacles to both
sides
More than 350 mm
(13-25/32 in.)
Outdoor unit installation
900 (35-7/16)
2-U-shape notched holes
(Base bolt M10)
500 (19-11/16)
Air inlet
Air outlet
Units should be installed by licensed contractor according to
local code requirements.
Unit : mm (inch)
PARTS TO BE PROVIDED AT YOUR SITE
(A) Power supply cord*
(B) Indoor/outdoor unit connecting wire*
(C) Extension pipe
(D) Wall hole cover
(E) Piping tape
Extension drain hose (or soft PVC
(F)
hose, 15 mm (19/32 in.) inner
diameter or hard PVC pipe VP16)
(G) Refrigeration oil
(H) Putty
(I) Pipe fixing band
(J) Fixing screw for (I)
(K) Wall hole sleeve
* Note:
Place indoor/outdoor unit connecting wire (B) and
power supply cord (A) at least 1 m (3 ft.) away from
the TV antenna wire.
The "Q'ty" for (B) to (K) in the above table is quan-
tity to be used per indoor unit.
1
1
1
1
1
1
Little
amount
1
2 to 7
2 to 7
1