Gaggia XE EVOLUTION Instrucciones De Uso página 38

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

ENGLISH
8 -
PURIFIER REGENERATION
IMPORTANT : Regenerate the purifier at the intervals listed
below:
HARDNESS °F
8 LITRE PURIFIER
From 00 to 20
regeneration after 1100 l.
From 21 to 30
regeneration after 850 l.
From 31 to 40
regeneration after 650 l.
From 41 to 60
regeneration after 450 l.
- place the empty 2 litre container under pipe E.
- shift levers C and D from left to right as shown in fig.8.2 and
remove the cover by loosening knob G, pour in 1.5 kg of sodium
chloride (coarse cooking salt) into the 8-litre purifier and 2 kg
into the 12-litre type.
- Replace the lid and shift lever from right to left as shown in
fig.8.3 and allow the salted water to drain out of pipe F until the
water is fresh.
- Shift lever D from right to left as shown in fig.8.4
A
WATER INLET
B
WATER OUTPUT
C
INLET TAP LEVER
D
OUTPUT TAP LEVER
E
DEPRESSURIZER PIPE
F
REGENERATION TUBE
G
COVER KNOB
12 LITRE PURIFIER
regeneration after 1600 l.
regeneration after 1250 l.
regeneration after 950 l.
regeneration after 650 l.
NB: These regeneration instructions are valid only provi-
ding the purifier is as that indicated in the figures. Should
it fail to correspond proceed as indicated in the instructions
attached to the purifier itself.
38

Publicidad

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Xd evolution

Tabla de contenido