Cleaning
 Clean the IP protective tubes regularly and in the event of soiling.
If possible, use an anti-static plastic cleaner. You thereby reduce the deposit of
dust particles on the IP protective tube caused by static charge.
Use no aggressive cleaning agents.
Use no abrasive cleaning agents.
 Remove soiling from the IP protective tube with plenty of water.
Avoid scratching.
 Afterwards, wipe off the IP protective tube with a clean, slightly damp cloth.
 Dry the IP protective tube with a clean cloth.
NOTICE
Observe after cleaning!
 Remove any residual water from the IP protective tube.
 Wipe off the IP protective tube with a clean cloth.
 Check the alignment of transmitter and receiver of the MLC safety light curtain
as described in the
 Test the effectiveness of the protective device as described in the
operating instructions

Technical data

Degree of protection
Degree of protection
Material
Plastic tube
End caps
Clamping cylinder
Pressure-equalization
membrane
Cable gland
Connection
Connection cable, 5-wire/8-wire, length 15 m
Dimensions
See dimensional drawing
original operating instructions
for the MLC safety light curtain.
IP 65, IP 66, IP 67, IP 69K
PMMA
V4A stainless steel (1.4404)
PA6
PA6
PA6
1
.
original
EN
11