Lasers", available from "www.laserinstitute.org". Many local governments, corporations, agencies, military and others, require all
lasers to be used under the guidelines of ANSI Z136.1. Laser Display guidance can be obtained via the International Laser
Display Association, www.laserist.org.
INSTALLATION
The installation of the fixture has to be built and constructed in a way that it can hold 10 times the weight for 1 hour
without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net. This
secondary safety attachment must be constructed in a way that no part of the installation can fall down if the main
attachment fails.
Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging and servicing.
The operator has to make sure that safety-relating and machine-technical installations are approved by an expert
before taking into operation for the first time and after changes before taking into operation another time.
The operator has to make sure that safety-relating and machine-technical installations are approved by a skilled
person once a year.
The fixture should be installed in the position where persons cannot reach and where persons may walk by or be
seated.
LASER SET UP & USAGE
This fixture has been designed to be hung. It is recommended for safety purposes, your lighting effect are properly mounted
using a suitable hanging clamp and safety cable. Items appropriate for safe and effective mounting are easily sourced from
your lighting vendor.
International laser safety regulations require that lasers must be operated in the fashion illustrated below, with a minimum of 3
meters (9.8 ft) of vertical separation between the floor and the lowest laser light vertically. Additionally, 2.5 meters of horizontal
separation is required between laser light and audience or other public spaces.
CAUTION:
Please consider the respective national norms during the
installation! The installation must only be carried out by
an authorized employee or dealers!
CAUTION:
When installing the device, make sure there is no highly
in inflammable material (decoration articles, etc.) in
between a distance of min o.5 meter.
CAUTION:
Use
of
adjustments,
performance
procedures other than
what
is
herein may result in
hazardous
exposure
controls,
or
of
specified
radiation