OBJ_BUCH-0000000298-001.book Page 19 Thursday, February 8, 2018 9:02 AM
Illumination (figure 10).
Never look or stare into the
WARNING
light of the power tool's lamp
from a short distance. Never point the light of
the lamp into the eyes of other persons in
close vicinity. The radiation produced by the
lamp can be harmful for the eye.
When pressing the On/Off switch, the light is
switched on.
After releasing the On/Off switch, the light
briefly stays on and then switches off auto-
matically.
Handling the battery.
Operate and charge the battery only within
the battery operating-temperature range of
0°C – 45°C (32°F –113°F). At the beginning
of the charging procedure, the battery tem-
perature must be within the battery operat-
ing-temperature range.
Battery charge-control indicator
(figure 11).
Press the button to activate the LED indication.
LED indicator Meaning
1 – 4 green
Percent-
LED
age of
charge
condition
Continuous
Battery is
red light
almost
empty
Red flashing
Battery is
light
not ready
for opera-
tion
The real percentage of the battery charge
condition is only indicated when the power
tool motor is stopped.
The electronics automatically switch off the
motor prior to the battery being deep dis-
charged.
Fig. 10
10 sec.
Fig. 11
Activity
Operation
Charge battery
Bring the battery
into the battery
operating-tem-
perature range,
then charge
en
=
=
LED indication on battery
≤
100 %
≤
75 %
≤
50 %
≤
25 %
=
0 %
19