Types Of Installation - Mastergrip 540139 Manual Del Propietário

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

PRESSURE SPRAYING
After selecting correct size fluid, set fluid pressure for the desired flow. Open atomization air and test
spray. If spray is too fine, then reduce air pressure. If spray is too coarse, then raise air pressure. Adjust
pattern width and repeat adjustment of spray.
Keeping fluid control screw in open position will reduce fluid needle wear.
NOTE: To reduce overspray and obtain maximum efficiency, always spray with the lowest possible
atomization air pressure.
Proper handling of the gun is essential for obtaining a good finish. The gun should be held at right
angle to the surface being covered, moving parallel with the surface. For precise control of the gun
and material, the trigger should be released before the end of the stroke.
Hold the gun from 6 to 12 inches (15,24cm to 30,48cm) away from the surface depending on material
and atomizing pressure. For a uniform finish, lap each stroke over the preceding stroke, making sure
the spray is smooth and wet.
Using the lowest possible atomizing air pressure will reduce over-spray and provide maximum efficiency.
6 to 12 inches
(15,24cm to 30,48cm)
Start
Pull
stroke
trigger
Coating will be light
at this point
WRONG
OPERATION
Coating should be even
and wet when spraying
TRAVEL OF GUN
Release
End of
trigger
stroke
RIGHT
Coating will be heavy
at this point
6

TYPES OF INSTALLATION

Air Inlet
Oil and Water
Extractor
Air Hose
Fluid
Siphon Cup
SIPHON FEED CUP HOOKUP
Air pressure for atomization is regulated at
extractor. Amount of fluid is adjusted by fluid
control screw on gun, paint viscosity and
air pressure.
Oil and Water
Extractor
Cup Regulator
Air
Fluid
Pressure Cup
PRESSURE FEED CUP HOOKUP
Air pressure for atomization is regulated at
extractor. Fluid pressure is regulated at cup
regulator. For heavy fluids and internal mix
nozzle spraying, fluid adjusted control screw on
gun, pressure cup also available less regulator.
Air
Air Supply
Pressure Tank
Fluid
PRESSURE FEED TANK HOOKUP
For portable painting operations
(Double regulator) Air pressure for atomization
and fluid supply is regulated by two individual
air regulators on tank.
Extractor
Air
Air
Pressure Tank
Fluid
PRESSURE FEED TANK HOOKUP
For medium production spraying
(Single regulator) Air pressure for atomization is
regulated at extractor. Fluid pressure is regulated
at tank regulator.
Fluid
Regulator
Extractor
Air
Fluid
PRESSURE FEED CIRCULATING HOOKUP
For heavy production spraying.
Air pressure atomization regulated at extractor.
Fluid pressure is regulated at fluid regulator.
7
Main Line
Outlet
Fluid

Publicidad