OBJ_BUCH-2029-005.book Page 21 Friday, September 8, 2017 10:36 AM
Batterydisplay, Battery in Charger
Indication
Meaning
When putting in charg-
28
x
er, display shows quan-
tity of previous recharg-
es for 1 minute, then
battery capacity with
bars filling.
Battery fully charged.
100
%
Display shows flashing
70
%
thermometer and bat-
tery symbol for
5 minutes:
– Battery is too hot
(between 50 °C–
70 °C). Battery can
be used in tool, but
not be charged.
– Battery is too cold
(under 0 °C)
No display shows:
– Battery is too hot
(over 80 °C)
– Battery is defective
Bosch Power Tools
English | 21
Measure
Allow battery to
charge on 100 %.
Leave indefinitely
in charger, or re-
move and store or
use.
Battery will not
charge until tem-
perature is within
limits:
– Let battery
cool down
– Let battery
warm up
– Charging can-
not start until
battery has
cooled down.
– Replace bat-
tery
2 609 932 876 | (8.9.17)