3.1 - 3.5 MPa 7.0 A
2.7 - 3.5 MPa 7.0 A
3.1 - 3.5 MPa 5.5 A
2.7 - 3.5 MPa 5.5 A
When you are finished:
DISCONNECTING HOSES
WARNING:
Risk of unsafe operation. Firmly grasp hoses in hand
when installing or disconnecting to prevent hose
whip.
Losing control of the hose may result in personal
injury and property damage.
7. Set the switch to OFF "O". Ensure compressor is
disconnected from the main supply.
NOTE:
Do not stop compressor by pulling out the plug.
8. Drain water from air tank by opening drain cock valve
at the side of air tank with locating at a level. WATER
WILL CONDENSE IN THE AIR TANK. IF NOT
DRAINED, WATER WILL CORRODE AND WEAKEN
THE AIR TANK AND PARTS CAUSING A RISK OF
AIR TANK RUPTURE.
WARNING:
Drain Air Tank Properly. Improper draining of the air tank
can result in corrosion of a parts and possible damaging
and bursting of the tank. Corrosion and damaging of a
parts, tank bursting could lead to personal injury and
property damage.
NOTE:
If drain valve is plugged, release all air pressure with air
tools and accessory equipments. If you are not able to do
so, arrange for repairs by MAKITA authorized dealer.
9. Using the air tool or accessory, bleed the tank
pressure down to zero.
10. Remove the air tool or accessory.
11. After the water has been drained, close the drain
valve. The air compressor can now be stored.
Air Consumption
Much
Little
MAINTENANCE
WARNING:
Never use the air compressor which is operating
abnormally.
If the air compressor appears to be operating
unusually, making strange noises or vibration, stop
using it immediately and arrange for repairs by
MAKITA authorized dealer.
WARNING:
Use only genuine Makita replacement parts.
Replacement parts not manufactured by Makita
may void your warranty and can lead to
malfunction and result in injuries. Genuine Makita
parts are available from an authorized dealer.
WARNING:
UNIT CYCLES AUTOMATICALLY WHEN POWER IS
ON. WHEN DOING MAINTENANCE, YOU MAY BE
EXPOSED TO VOLTAGE SOURCES, COMPRESSED
AIR OR MOVING PARTS. PERSONAL INJURIES
CAN OCCUR. BEFORE PERFORMING ANY
MAINTENANCE OR REPAIR, UNPLUG THE
COMPRESSOR AND BLEED OFF ALL AIR
PRESSURE.
WARNING:
Do not modify the compressor.
Do not modify the compressor. Always contact the
authorized service facility any repairs.
Unauthorized modification may not only impair the
compressor performance but may also result in
accident or injury to repair personnel who do not
have the required knowledge and technical
expertise to perform the repair operations
correctly.
To ensure efficient operation and longer life of the air
compressor unit, a routine maintenance schedule should
be prepared and followed. The following routine
maintenance schedule is geared to a unit in a normal
working environment operating on a daily basis. If
necessary, the schedule should be modified to suit the
conditions under which your compressor is used. The
modifications will depend upon the hours of operation and
extremely dirty and/or hostile environment will require a
greater frequency of all maintenance checks.
ROUTINE MAINTENANCE
SCHEDULE
1. Drain water from the air tank, any moisture separators
or air filter regulators.
2. Check for any unusual noise and/or vibration.
3. Check the pressure censor to make sure they are
operating properly.
WARNING:
Risk of bursting.
Check the pressure censor. If the pressure censor or
relief valve does not operate properly over
pressurization of the air tank may result in rupture or
9