6. It's recommended to test the alarm system for correct operation with first
use and every 3 months.
Procedure:
a) Switch the alarm unit on to ALARM or CHIME (for testing
recommended).
b) Push the ON button on the remote control to arm the alarm.
c) Wait for 20~25 seconds (delay time).
d) Open every door or window one by one and check if the corresponding
LED lights up and the CHIME sounds.
e) Disarm the alarm if everything operates correct.
f) The alarm system is ready to use.
Note:
1) The alarm unit will give a conformation tone when armed or disarmed. The
tone for CHIME is different as for ALARM.
2) If a sensor does not need to be switched on, it's possible to switch off every
sensor individually with the on/off switch. In this case the sensor is no part
of the alarm system anymore when armed.
3) A sensor switched to RF+ALARM will always give an alarm sound on the
sensor itself, unless the alarm unit is armed or disarmed.
4) When a sensor is triggered and the siren of the alarm unit sounds, it needs
to be switched off with on/off switch of the alarm unit. After that the alarm
unit can be switched on again. When the alarm keeps on going after arming
the system, check if every door or window is closed properly.
Installation SAS-ALARM110
1. Insert, according the diagram inside the battery compartment, (backside)
the batteries for the alarm unit (3x AA).
2. Install the door/window sensor with the adhesive tape to doors and
windows. Note: maximum 1 cm distance between magnetic contact and
sensor (see figure 2). Switch on the sensor to RF or RF+ALARM. If switched
to RF+ALARM, the sensor will send, when triggered, a signal to the alarm
unit and the siren of the sensor itself will also sound. In this case the siren of
the sensor and the alarm unit will both sound.
3. Install the vibration sensor with the adhesive tape to windows (on the
glass). Switch on the sensor to RF or RF+ALARM. If switched to RF+ALARM,
the sensor will send, when triggered, a signal to the alarm unit and the siren
of the sensor itself will also sound. In this case the siren of the sensor and
the alarm unit will both sound. Note: the vibrate sensor is very sensitive.
6
ENGLISH

Publicidad

loading

Este manual también es adecuado para:

Sas-alarm110Sas-alarm120Sec-alarm100Sec-alarm110Sec-alarm120