Technical description
• Overloading of the mains priority circuit and short circuit shutdown:
The LED on the inverter indicates an operating fault when an excess load is
connected or a short circuit has occurred. The fuse in the device must be pressed
in again by hand after it is triggered by excess current.
I
NOTE
The individual values are found in the chapter "Technical data" on
page 23.
The inverter can be operated in the following net configurations:
• TN network:
The neutral conductor of the inverter is grounded. A downstream safety switch
(RCD) must be installed.
• IT network:
Both phases are insulated. This is suitable for operating one load. If more than
one load will be connected a protection plan has to be set up (e. g. insulation
monitor).
The network configuration is set via a DIP switch at the device.
The inverters DSP13xxT, DSP18xxT, DSP23xxT have a connection cable with socket
and plug. The inverter DSP35xxT is directly connected at the terminals via the PG
glands.
Due to the phase synchronisation the inverter adapts to the phase of the AC input
voltage. Thereby voltage peaks are prevented when switching from battery to
mains.
The inverter is suitable for operating sensitive consumers because the output voltage
is a pure sinus wave.
The inverter is fitted with a priority circuit. If an external 230 Vw voltage is available,
this will have priority. If no external 230 Vw voltage is connected, then the con-
nected battery will be used as the power supply.
The inverter can be switched to an energy-saving mode to prevent the connected
battery from discharging too quickly.
The inverter can be turned on or off using the remote control (accessory).
Additionally, the inverter can be controlled using the energy monitor (accessory).