Connecting the inverter
8
Connecting the inverter
8.1
General instructions
!
WARNING!
• The inverter may only be connected by a qualified workshop. The
following information is intended for technicians who are familiar
with the guidelines and safety precautions to be applied.
• Never use the inverter on vehicles where the positive terminal of the
battery is connected to the chassis.
• If you do not fit a fuse to the positive cable, the cables can over-
load, which might result in a fire.
• When installed in vehicles or boats, the inverter must be connected to the chassis
or earth.
• When setting up a socket distribution circuit (mains setup), comply with the
applicable regulations.
• Only use copper cables.
• Keep the DC cables as short as possible (< 1 m).
• Keep to the specified cable cross section and fit a cable fuse (fig. 7 1) as close
to the battery as possible on the positive cable (see the table).
Device
DSP612
DSP624
DSP1012
DSP1024
DSP1512
DSP1524
DSP2012
DSP2024
12
Required cable
cross section
25 mm²
25 mm²
35 mm²
25 mm²
50 mm²
25 mm²
70 mm²
35 mm²
SinePower
Cable fuse
150 A
150 A
200 A
150 A
250 A
150 A
300 A
200 A
EN