8. Installation, relocation, and inspection
Warning:
Repair or relocation should not be done by the customer.
If this is done incorrectly, it may cause a fire, electric shock, injury by dropping of the unit, water leakage, etc. Consult your dealer.
Disposal
• To dispose of this product, consult your dealer.
<Installation for Remote-Controller>
■ Use the remote controller holder that is provided to avoid misplacing the remote controller.
■ Install the remote controller in a location that meets the following conditions.
• Out of the direct sun light
• Away from any heat sources
• Out of the airflow from the air conditioner (cool or warm)
• Where the operation of the remote controller can easily be performed, and the display is readily visible to the user
• Out of the reach of small children
NOTES:
* If there is a fluorescent light in the room in which the air conditioner is to be installed, turn it on and make sure that the
signal from the remote controller can be received by the indoor unit from the intended installation location. When the
signal receiving unit receives a signal from the remote controller, a short beeping sound will be heard.
If the air conditioner unit is installed in a room in which a fluorescent light on an electronic lighting control system
(i.e., inverter light) is installed, signal interference may occur.
* Maximum signal receiving distance is approximately 7 meters (Approx. 22 feet). Signal receiving angle is approximately
45 degrees to the right and the left from the center.
* Install the unit at least 1 meter (Approx. 3 feet) away from the TV or radio.
(If the unit is installed too close to these appliances, signal interference (picture distortion and noise) may occur.)
■ Use the tapping screws that are provided to mount the remote controller holder on the wall, and then place the remote
controller in the holder.
NOTES:
<Functions not supported by older versions of signal receiving unit >
• Temperature setting in 1 °F increments.
• Control operations that are performed on the controller with the setting other than "Standard 2 °F".

9. Specifications

Model
Power supply
Input (Indoor only)
kW
Current (Indoor only)
A
Airflow (Lo-Mid-Hi)
CMM
Ext. static pressure
Pa
Noise level (Lo-Mid-Hi)
dB
Dimension (H×W×D)
mm
Weight
kg
Notes: 1. Specifications subject to change without notice.
2. The external static pressure is set to 15 Pa at factory shipment.
If you have any question, consult your dealer.
SEZ-M25DAL
SEZ-M35DAL
0.04
0.05
0.39
0.46
5.5-7-9
7-9-11
5/15/35/50
5/15/35/50
23-26-30
23-28-33
200×790×700
200×990×700
17.5
21
SEZ-M50DAL
~/N, 230V, 50Hz/220-230V, 60Hz
0.07
0.63
10-12.5-15
5/15/35/50
30-34-37
200×990×700
22
SEZ-M60DAL
SEZ-M71DAL
0.07
0.10
0.63
0.84
12-15-18
12-16-20
5/15/35/50
5/15/35/50
30-34-38
30-35-40
200×1190×700
200×1190×700
25.5
25.5
9