F1000-UPS OWNER'S MANUAL
NOTE: To store your F1000-UPS for an extended period, cover it and store with the battery fully charged. Recharge the battery
every three months to ensure battery life.
OPERATION
FRONT PANEL DESCRIPTION
Power Switch
Press and hold the power button for 2 seconds to turn the F1000-UPS ON or OFF.
Menu Navigation Knob
Rotate clockwise to navigate to the next screen, counter-clockwise to return to the previous screen, push to select menu item.
IR Detector
IR Detector, for sampling IR remote control signals.
Removable Battery Access Panel
Easy to remove for battery access and replacement.
FRONT PANEL DISPLAY LED DESCRIPTIONS
Status Display
LCD displays status and menu navigation items
Outlet Bank 1 Indicator
Illuminated blue when outlet bank 1 is switched on
Outlet Bank 2 Indicator
Illuminated blue when outlet bank 2 is switched on
Line Fault Indicator
This LED will illuminate in red to warn the user that a wiring problem such as a bad/missing ground or reversed wiring exists within
the AC receptacle. If illuminated, disconnect all equipment and contact an electrician to insure outlet is properly wired.
REAR PANEL DESCRIPTION
Outlet Bank 1 - Critical Load Outlets
Four battery powered, SMP protected outlets for critical-load equipment insures temporary uninterrupted operation of connected
equipment during a power failure.
Outlet Bank 2 - Non-Critical-Load Outlets
Four battery powered, SMP protected outlets for connected equipment insures temporary uninterrupted operation of connected
equipment during a power failure. These outlets will shut off when the batteries drain to a designated level to reserve remaining bat-
tery charge for the critical load outlets.
IR Control Section
Indicator LED's – Indicates status
IR Output Jacks – Standard 1/8" (3.5mm) mono jack for connection to an IR flasher (IR flashers not included)
Circuit Breakers for Overload Protection
Resettable circuit breakers provide optimal overload protection.
RS-232 Serial Communication Port
The serial port allows connection and communication between the F1000-UPS and an automation or computer system. This allows
the installer to program a number of variables including the Critical Load Battery Threshold.
See the software documentation for more information.
AC Power Cord
Captive, heavy-duty shielded power cord.
USB to Computer
USB port allows communication between F1000-UPS and computer.