Manufacturer (Cos) / Alarm (All); Branch Parameters; Description Of Alarms; High Temperature Alarm - AERMEC SWP200 Manual De Usuario

Pompe di calore acqua calda sanitaria
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

12.7.
MANUFACTURER (COS) / ALARM
(ALL) BRANCH PARAMETERS
Param.
default
limits
AL1
120
0-255
AL2
5
0-255
AL3
5
0-255
AL4
10
0-255
AL5
70
H06 -80 °C/°F
AL6
10
0-255
AL7
5
0-255
12.8.

DESCRIPTION OF ALARMS

HIGH
PRESSURE
ALARM:
is
automatic
until
the
interventions/hour equals the value
set in parameter AL7, in which case it
switches to manual. In this case resetting
takes place via the keypad, by pressing
the SET button, once the external cause
has disappeared.
The intervention causes the machine to
switch off and the label E01 to appear
on the display.
LOW
PRESSURE
ALARM:
is
automatic
until
the
interventions/hour equals the value
set in parameter AL2, in which case it
switches to manual.
When the compressor starts up, this
alarm is concealed for a period equal
to the value of parameter AL1.
Resetting takes place in the same way
as for the High pressure alarm.
The intervention causes the machine to
switch off and the label E02 to appear
on the display.
S1 PROBE FAULT ALARM: this is activated
if probe S1 (boiler water probe) is short-
circuited or cut off.
The intervention causes the machine to
switch off and the label E03 to appear
on the display.
S2 PROBE FAULT ALARM: this is activated
if probe S2 (outside air probe) is short-
circuited or cut off.
The intervention causes the machine to
switch off and the label E03 to appear
on the display.
HIGH TEMPERATURE ALARM: resetting
takes
place
automatically.
activated if probe S1 assumes values
over parameter AL5 for a time period
exceeding parameter AL6.
The intervention causes the machine to
switch off and the label E01 to appear
on the display.
CAUTION: when an alarm status
occurs, press and hold the SET button
for 3 seconds to access the navigation
diagram.
Parameters U01, U02, H01 - H22, AL1-AL6,
unit
sec.
the operating hours and the hour count
no.
for the anti-bacterial cycle are stored in
sec.
the memory. The operating hours and
anti-bacterial cycle mangement count
sec.
stops if the power supply is cut off, and
is resumed from its status immediately
sec.
prior to the power supply stoppage.
no.
If the operator notes the repeated
occurrence
switch off the machine and contact
AERMEC S.p.A or one of its authorised
technical service centres, quoting the
unit identification data provided on the
relevant data plate.
resetting
13.

CHECKS BEFORE START-UP

number
of
Check the following before activating
the unit:
The
earth
correctly;
The power socket is fi tted with a
protective fuse;
The plugs are inserted correctly.
resetting
number
of
13.1.

ROUTINE MAINTENANCE

WARNINGS: before
undertaking any maintenance work,
make sure that the machine is not - and
cannot accidentally be - connected to
the power supply.
The electronic power supply must
therefore be disconnected every time
maintenance work is carried out.
The customer is responsible for
ensuring all necessary maintenance
work is performed on the heat
pump.
Only
qualifi ed personnel may carry out
maintenance work.
If the unit needs to be disassembled,
safety gloves should be worn to
protect the hands.
13.2.

QUARTERLY CHECKS

Check that all electrical connections
It
is
are securely fastened.
Check the calibration values and
the programming parameters.
Check the condition of the fan and
compressor contacts.
Check the hydraulic circuit fi lters.
Check the sacrifi cial anode.
Check the system safety valve is
of
the
above
alarms,
wire
is
connected
suitably
trained
and
working properly.
Check the system expansion tank
pre-load.
Check the overall condition of the
unit and the system as a whole and
make sure there are no leaks.
13.3.
ANNUAL CHECKS AT EACH
START-UP
Check the refrigerant charge.
Check the fi lter-dryer fi lter.
Check the cooling circuit for signs of
wear.
Check the electric heating element.
Check the bolts, nuts, fl anges and
water connections are fastened
securely, as vibrations could have
loosened them.
SWP_5287500_00
61