Lamp (Re)Placement; Overhead Rigging - JB Systems Light BLACK LIGHT TL-40 PRO Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 11
ENGLISH
DESCRIPTION:
1. Hanging brackets + knobs
2. 3 Fixation screws
3. 2 Hinges
4. Protective grid + reflector
5. Mains input with IEC socket and integrated fuse holder.

LAMP (RE)PLACEMENT

In case of replacement of the lamp or maintenance, do not open the fixture within 10
minutes until the unit cools down after switching off. Always unplug the unit before
servicing! Always use the same type of spare parts (bulbs, fuses, etc.) When
replacing parts, please only genuine spare parts.
 Switch the unit off and unplug the mains cable.
 Wait for about 5 minutes until the unit has been cooled down.
 Unscrew the fixation screws and open the protective grid
 Unplug the old lamp by turning it gently over 90° and pulling it out of the lamp sockets.
 Insert the new UV lamp in the lamp socket and turn it gently over 90°
Attention! Check the label on the backside of the device or see the technical specifications in this manual
to know which lamp should be used.
 Close the protective grid again and tighten the fixation screws
 Done!

OVERHEAD RIGGING

 Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.
 Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.
 Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed at least 50cm from surrounding walls.
 The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.
 Before rigging make sure that the installation area can hold a minimum point load of 10times the device's
weight.
 Always use a certified safety cable that can hold 12times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.
 The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!
 Don't cover any ventilation openings as this may result in overheating.
 The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.
JB SYSTEMS®
OPERATION MANUAL
3/24
BLACKLIGHT STRIP
ENGLISH
OPERATING INSTRUCTIONS
 Once connected to the mains you can switch the device on/off with the mains switch.
 The UV lamp needs 3-4 minutes warm-up time until it reaches full lighting output.
 Regular breaks during operation are essential to maximize the life of this device as it is not designed for
continual use.
 Do not switch the unit on and off in short time intervals as this reduces the lamp life.
 The lamps' surface temperature may reach up to 80°C. Don't touch the lamp with bare-hands during its
operation.
 Always unplug the unit when it is not used for a longer time or before replacing the bulb or start servicing.
 In the event of serious operating problems, stop using the fixture and contact your dealer immediately.
 Important: Never look directly into the light source! Don't use the effect in the presence of persons
suffering from epilepsy.
MAINTENANCE
 Make sure the area below the installation place is free from unwanted persons during servicing.
 Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
During inspection the following points should be checked:
 All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
 Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
 When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.
 The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
 In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.
 The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.
 The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit's optics.
 Clean with a soft cloth using normal glass cleaning products.
 Always dry the parts carefully.
 Clean the external optics at least once every 30 days.
 Clean the internal optics at least every 90 days.
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!
SPECIFICATIONS
Mains Input:
AC 230V, 50Hz
Fuse:
T1A ~ 250Vac (20mm glass)
Lamp:
T8-36W 120cm UV-lamp with G13 fittings
Size:
1260 x 130 x 95 mm
Weight:
4,5kg
Every information is subject to change without prior notice
You can download the latest version of this user manual on our website: www.beglec.com
JB SYSTEMS®
OPERATION MANUAL
4/24
BLACKLIGHT STRIP

Publicidad

Tabla de contenido
loading

Tabla de contenido