Mounting

Pressure reducer 7077/3 always has to
be operated in vertical position on a CO2
cylinder.
The pressure reducer has been manufactured
in Europe for use on cylinders with a thread in
keeping with German standard DIN 477. The
designation of the thread is W 21.8 x 14. The
US model has the standard thread CGA 320
with another gland with thread.
Before connecting the pressure reducer to the
filled CO2 cylinder, use the pressure adjusting
screw (K) to close the valve (turn the screw
out, pressure = 0).
Use the union nut (S) to fit the pressure
reducer 7077/3 to the CO2 cylinder (V).
Please make sure that the sealing ring is dry
and not soiled or damaged. Next day, check
the fit of the union nut (S), and retighten, if and
when necessary.
Use the fine adjustment valve (L) to connect
the mounted CO2 unit to the gas outlet (O)
(see page 2: Example of use: Comline dosing
plant).

Montage

Le réducteur de pression 7077/3 doit toujours
être monté verticalement sur sa bouteille de
CO2.
Le réducteur de pression en version Europe
possède un filetage W 21,8 x 14 suivant
DIN 477. La version US possède un filetage
CGA 320 avec un embout différent.
Avant le raccordement du réducteur de
pression sur la bouteille de CO2, il est
important de fermer la vis de réglage (K) (sens
anti-horaire = pression nulle).
A l'aide de l'écrou de serrage (S), montez le
réducteur de pression 7077/3 sur la bouteille (V).
Veillez à ce que le joint d'étanchéité soit sec,
propre et non endommagé. Après une journée
d'utilisation, vérifiez à nouveau le bon serrage
de l'ensemble et effectuez un resserrage
si nécessaire. Raccordez l'utilisation CO2
à la sortie du réducteur de pression (O) au
niveau de la vis de réglage fin (L) (voir page 2,
Exemple d'installation de dosage Comline).
7