Specific Operating Instructions
1
2
3
a.) Installation
Fastening holes (4) are provided for wall mounting. The unit must be mounted against a vertical, fireproof wall
with the connections at the bottom, see above picture, left part. For outside installation the device must also
be protected against exposure to rain and direct sunlight.
b.) Functional description of the appliance
Commission device WITHOUT fence and connection to earth. The control lights flash in time to the impulses
(green or red). The device is ready for operation. If control lights do not flash, the power supply or power
supply line must be checked first. If no fault can be detected, the device should be tested by a specialist.
c.) Functional description with CONNECTED fence system (earthing + fence)
Flashing green:
Control light
fence
Flashing red:
1
(1)
Flashing green:
Control light
Flashing
2
earth (2)
red:
The unit can be operated with a SEPARATE fence system connected to each fence connection (6 – 7).
If both fence exits are used simultaneously, the control light (1) refers to exit (7) with maximum energy.If the indicator
light flashes faster than once per second, the appliance must be disconnected at once and checked by a
technician before it can be used again.
New function in accordance with EN 60335-2-76 A12: 2010
After a delay time of 15 seconds this device is able to deliver output energy of over 5 joules.
With an increasing load the device increases its output energy after a delay time has lapsed and therefore automatically
adjusts the shock strength to the increased growth, weather conditions and fence status.
If the device is operating with a lower load (more than 1000 Ohm) and the load suddenly increases so significantly that
the load resistance drops below 400 Ohm for more than 6 pulses then the device goes into an alarm mode.
The pulse interval is then extended to 3 seconds, the device issues an acoustic and visual alarm (all signal lights flash
rapidly in red).
If the load lasts more than 10 minutes then the alarm ends and the system switches back to the normal pulse frequency.
If the load drops again within 10 minutes of switching on the alarm and the load resistance thereby exceeds 600 Ohm,
the alarm is cancelled and the device resumes normal operation.
!!!Should the device be in the alarm mode, it must be switched off immediately and the fence arrangement be checked!!!
Any user of electric fence systems is legally indebted to control the fence-appliance and the fence system regularly, in
accordance with the conditions of use, at least once per day.
visual check of the appliance and the fence system
-
measurement of the minimum voltage of 2500V at each point of the fence
-
-
Ensure a good grounding of the devices, with at least 3 ground rods, Item No.: 44219.
4
6
5
7
Mains plug is used as ON / OFF!
Connection to
This energizer shall not be used as an animal
trainer (inside a barn).
State of fence ok = output voltage > 3500V = minimum requirement
State of fence faulty = output voltage ≤ 3500V, see operating instructions
enclosed, possible sources of error (fig. 2, pg.5)
State of connection to earth ok; earth voltage < 1000 V
State of connection to earth faulty, earth voltage ≥ 1000 V, see operating
instructions enclosed, possible sources of error (fig. 2, pg.5) and connection to
earth (pg.4)
1
2
3
4
5
6
230 V ~!
7
3
NVi 9000
Indicator light fence
Indicator light earth
230V-Consumption
announcement in %
(25% = green; 50 - 100% = red)
Fastening holes
Earth connection
Fence connection
with reduced energy
Fence connection
with maximum energy
-EN-