Errors And Faults - Trotec TTK 175 S Manual De Instrucciones

Ocultar thumbs Ver también para TTK 175 S:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 54

Errors and faults

The accurate functionality of the device was tested
during production a number of times. However, if
functionality faults do occur, then check the device
according to the following list.
The device does not start:
• Check the mains power
(230 V/1~/50 Hz).
• Check the mains plug for damages.
• Have the electrics checked by a specialist compa-
ny for cooling and air-conditioning or by TROTEC
The device runs but forms no condensation:
• Check the condensation tank is positioned correct-
ly. Check the fill level of the condensation tank and
empty it if necessary. The condensation tank indi-
cator light must not light up.
• Check the condensation tank is not dirty. If neces-
sary, clean the condensation tank.
• Check the room temperature. Check the device's
permissible working range complies with the tech-
nical data.
• Ensure that the relative humidity complies with the
technical data.
• Check that the selected humidity is realistic. The
humidity in the room must be above the selected
range. Reduce the selected humidity by turning
the rotary switch, if necessary.
• Check the air filter is not dirty. If necessary, clean
or replace the air filter.
GB
• From the outside, check the condenser is not dirty
(see chapter "Maintenance"). If your condenser is
dirty, have it cleaned by a specialist company for
cooling and air-conditioning or by TROTEC
The device is loud or vibrates; condensation leaks:
• Check whether the device is standing upright and
on an even surface.
The device gets very warm, is loud or is losing
performance:
• Check the air inlets and air filter are not dirty. Re-
move external dirt.
®
.
• Check the inside of the device and especially the
fan, the fan housing, the evaporator and the con-
denser for external dirt (see chapter "Mainte-
nance"). If the inside of the device is dirty, have it
cleaned by a specialist company for cooling and
air-conditioning or by TROTEC
Does your device still not operate correctly after
these checks?
Bring the device to a specialist company for cooling
and air-conditioning or to TROTEC
Operating Manual – Dehumidifier TTK 175 S
®
.
®
.
®
for repairs.
B - 11

Publicidad

Tabla de contenido
loading

Tabla de contenido