Balluff BFT Serie Manual De Instrucciones página 10

Ocultar thumbs Ver también para BFT Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Screw-in thermometer with plug connection
BFT _ _ _ _-_ _001-R_ _A0A-_ _
Disposal
Medium remnants on the device may result in a hazard to
the operator and the environment. Take appropriate
precautionary measures and dispose of the device
properly.
Observe the national regulations for disposal.
4
english
Technical data
Detection range / measuring range
Measuring element
Limit deviation for the
measuring element per
IEC 60751
Response time per
IEC 60751
Measuring range
Electric data
Connector
Mechanical data
Probe diameter
Housing material
Ambient conditions
Ambient temperature
Storage temperature
Degree of protection per
IEC 60529
Vibration resistance per
IEC 60068-2-6
1)
Shock resistance per
60068-2-27
1)
Pressure resistance
1)
1) depends on installation situation, medium and temperature
Pt1000
Class B
±(0.3 °C + 0.005 |t|)
T05 < 2.5 s; T09 < 6.5 s
–50...+150 °C
(–58...+302 °F)
M12, 4-pole
6 mm
Stainless steel
–40...+100 °C
(–40...+212 °F)
–40...+85 °C
(–40...+185 °F)
IP66/IP67 (when attached)
≤ 10 g
≤ 500 g
≤ 50 bar (725 psi)

Publicidad

Tabla de contenido
loading

Tabla de contenido